MSI-H Series Linear Position Sensor with Start/Stop Output
The MSI-H series is a rod-type, high-precision, absolute, non-contact magnetostrictive linear position sensor with a measuring range from 25 to 3800 mm.
Position measurement is performed using ring-type position magnets that move along the waveguide without physical contact. The sensor flange is made of high-quality stainless steel and designed for long-term operation in demanding industrial environments.
Price on request
Design features
- Full compatibility with Temposonics protocols
- Modular design allows fast replacement without depressurizing the hydraulic circuit
- Compatible with all Temposonics position magnets and selected BALLUFF magnets
- Zero position offset of 50 mm, 30 mm, or customer-specific value
- Absolute linear measurement (output signals proportional to magnet displacement)
- LED status indicator for diagnostics
- High accuracy: resolution up to 5 µm
- Measuring length from 25 to 3800 mm (1 mm increments)
- Linearity < 0.01 %
- Repeatability < 0.001 %
- Operating temperature up to +85 °C
- Optional operating pressure up to 800 bar
- Protection class IP67
- The sensor supports the use of water-resistant and Teflon cables.
Configurator
MSI-H
.
_
.
_
.
_
.
_
_
.
R
_
MSI-H Series Linear Position Sensor with Start/Stop Output, order code:
Scope of delivery
THE SCOPE OF SUPPLY INCLUDES: | |
Linear position sensor | |
Certificate of Conformity | |
Manual | |
Warranty card | |
Mating connectors and magnets for the sensor must be ordered separately! | |
Product ordering code
TECHNICAL REQUIREMENTS FOR ORDER PLACEMENT | |||||||||||||||||||
1 | 2 | 3 | 4 | 5 | 6 | ||||||||||||||
MSI-H | . | S | . | 0 | 5 | 0 | 0 | . | T | . | D60 | . | R01 | ||||||
1 | Series: MSI-H - Rod-type | ||||||||||||||||||
2 | Flange type: M – M18 × 1.5, rod Ø10 mm S – 3/4”-16 UNF, rod Ø10 mm R – M18 × 1.5 with M4 thread on rod end, Ø10 mm Z – 3/4”-16 UNF with M4 thread on rod end, Ø10 mm T – 3/4”-16 UNF with raised face, Ø10 mm V – M18 × 1.5 with FKM seal, Ø10 mm U – 3/4”-16 UNF with raised face, FKM seal, Ø10 mm H – 3/4”-16 UNF, FKM seal, Ø10 mm L – 3/4”-16 UNF, rod Ø7 mm K – M18 × 1.5, rod Ø7 mm | ||||||||||||||||||
3 | Measuring range: 0025...3800 mm, 5 mm step Other lengths available on request | ||||||||||||||||||
4 | Zero point: T - 50 mm B - 30 mm | ||||||||||||||||||
5 | Connection: D60 – 6-pin male connector, M16 R02 – PVC cable without connector, 2 m; option: R01...R20 (1...20 m) H02 – PUR cable without connector, 2 m; option: H01...H20 (1...20 m) T02 – Teflon cable without connector, 2 m; option: T01...T20 (1...20 m) S02 – Silicone cable without connector, 2 m; option: S01...S20 (1...20 m) W02 – Water-resistant cable without connector, 2 m; option: W01...W20 (1...20 m) | ||||||||||||||||||
6 | Output signal: R01 – Start/Stop R5 – Start/Stop for injection molding machines | ||||||||||||||||||
Technical specifications
OUTPUT PARAMETERS | ||||
Measured value | Position | |||
Operating range, L | 25 — 3800 mm, 1 mm step | |||
Velocity | 0.025 - 10 m/s | |||
Displacement speed | Any | |||
Update rate | 0.5 ms up to 1200 mm; 1.0 ms up to 2400 mm; 2.0 ms up to 3800 mm; | |||
Status diagnostics | LEDs next to the connector | |||
INTERFACE | ||||
Digital interface | RS-485/422 | |||
Data transfer protocol | Start/Stop | |||
Number of magnets | 1 | |||
Max cable length | For stable operation, it is recommended to use a cable no longer than 50 meters | |||
POSITION MEASUREMENT ACCURACY | ||||
Linearity | < ± 0.01% F.S. (minimum ± 40 µm) | |||
Repeatability | < ± 0.001 % F.S. (minimum ± 2.5 µm) | |||
OPERATING CONDITIONS | ||||
Operating temperature | -40 °C…+105 °C | |||
Rated pressure | 350 bar, 600 bar peak (optional 800 bar) | |||
Humidity | 90 % rel. humidity, no condensation | |||
Ingress protection | IP65, IP67 at cable outlet | |||
MATERIALS | ||||
Sensor electronics housing | Aluminum, plastic | |||
Sensor rod | Stainless steel ASTM A269-13 / TP304l (10x1.5) | |||
Flange | Stainless steel 08Х18Н10 / AISI 304 | |||
MOUNTING | ||||
Mounting position | Any orientation. For horizontal installation of sensors with an operating range exceeding 1000 mm, the rod must be supported or fixed at the end | |||
Flange parameters | Flange thread M18х1.5 or 3/4" - 16 UNF | |||
Position magnet mounting | Mounting hardware and screws made of non-magnetic material | |||
ELECTRICAL CONNECTION | ||||
Operating voltage | 9..28 VDC | |||
Reverse polarity protection | up to –30 V DC | |||
Overvoltage protection | up to 36 V DC | |||
Current consumption | 50…140 mA (depending on sensor length) | |||
Insulation resistance | 500 V DC (between sensor housing and 0 V DC) | |||
STANDARDS, EMC TESTS | ||||
Shock test | 100 g, single shock according to IEC 60068-2-7 | |||
Vibration test | 15 g / 10–2000 Hz according to IEC 60068-2-6 | |||
EMC tests | GOST R IEC 61326-1-2014 | |||
Connection: cable outlet
CABLE | D60 | FUNCTION | |
Black | 1 | Stop (-) | |
White | 2 | Stop (+) | |
Yellow | 3 | Start (+) | |
Green | 4 | Start (-) | |
Red | 5 | +24 VDC (-15% / +20%) | |
Blue | 6 | 0 VDC (power supply) | |
Connection: D60 connector
PIN ASSIGNMENT | PIN | FUNCTION |
![]() M16 male connector (view from sensor side) | 1 | Stop (-) |
2 | Stop (+) | |
3 | Start (+) | |
4 | Start (-) | |
5 | +24 VDC (-15% / +20%) | |
6 | 0 VDC (power supply) |
Interface
DIGITAL INTERFACE START/STOP |
![]() The "Ready" signal generation indicates a new measurement cycle and occurs in the Start/Stop module simultaneously with the "Start" signal. After the "Start" signal is generated, the Start/Stop module switches to line listening mode and waits for the "Stop" signal from the linear position sensor. The time difference (dt) between the "Start" and "Stop" signals is directly proportional to the position of the position magnet. |
Connection example
CONNECTION DIAGRAM (DUPLEX) |
![]() |
CONNECTION DIAGRAM (HAIF-DUPLEX) |
Setting
Status diagnostics
LED DIAGNOSTICS | GREEN | RED | STATUS |
![]() | Off | Off | No power supply or sensor fault |
On | Off | Normal operation | |
On | On | No position magnet or incorrect number of magnets | |
Flashing | Off | Programming mode ( analog output only) |
Interchangeability
| MSI | Balluff | Temposonics |
|---|---|---|
| MSI-H EtherCAT | BTL7 -Y/Z- Series – EtherCAT | R-Series V RH5 EtherCAT |
| MSI-H Profinet | BTL7 -Y/Z- Series - Profinet | R-Series V RH5 Profinet |
| MSI-H Analog | BTL7 -Y/Z- Series - Analog voltage | R-Series V RH5 Analog |
| MSI-H SSI | BTL7 -Y/Z- Series – SSI | R-Series V RH5 SSI |
| MSI-H Analog | BTL7 -Y/Z- Series - Analog current | R-Series V RH5 Analog |
| MSI-H SSI | BTL7 -A/B- Series – SSI | R-Series V RH5 SSI |
| MSI-H EtherCAT | BTL7 -A/B- Series – EtherCAT | R-Series V RH5 EtherCAT |
| MSI-H Profinet | BTL7 -A/B- Series – Profinet | R-Series V RH5 Profinet |
| MSI-H Analog | BTL7 -A/B- Series - Analog voltage | R-Series V RH5 Analog |
| MSI-H Analog | BTL7 -A/B- Series - Analog current | R-Series V RH5 Analog |
| MSI-H CANopen | BTL5 -Y/Z- Series – CANopen | R-Series RH CANopen |
| MSI-H Profinet | BTL5 -Y/Z- Series – Profibus | R-Series V RH5 Profinet |
| MSI-H CANopen | BTL5 -A/B- Series - CANopen | R-Series RH CANopen |
| MSI-H Profibus | BTL5 -A/B- Series - Profibus | R-Series RH Profibus |
| MSI-H Start/Stop | BTL7 -BE/BF- Serie - Digital | E-Series EH Start/Stop |
| MSI-H SSI | BTL7 -BE/BF- Serie – SSI | R-Series V RH5 SSI |
| MSI-H Start/Stop | BTL7 -ZE/ZF- Serie – Digital | E-Series EH Start/Stop |
| MSI-H SSI | BTL7 -ZE/ZF- Serie – SSI | R-Series V RH5 SSI |
| MSI-H Start/Stop | BTL7 -CE- Serie – Digital | E-Series EH Start/Stop |
| MSI-H SSI | BTL7 -CE- Serie – SSI | R-Series V RH5 SSI |
| MSI-H Start/Stop | BTL7 -CD- Series – Digital | E-Series EH Start/Stop |
| MSI-H Analog | BTL7 -CD- Series - Analog voltage | R-Series V RH5 Analog |
| MSI-H SSI | BTL7 -CD- Series – SSI | R-Series V RH5 SSI |
| MSI-H Analog | BTL7 -CD- Series - Analog current | R-Series V RH5 Analog |
| MSI-H CANopen | BTL5 -W- Series – CANopen | R-Series RH CANopen |
| MSI-H CANopen | BTL5 -WB- Series - CANopen | R-Series RH CANopen |
| MSI-H Start/Stop | BTL5 -WB- Series – Digital | E-Series EH Start/Stop |
| MSI-H Start/Stop | BTL5 -W- Series – Digital | E-Series EH Start/Stop |
| MSI-H CANopen | BTL5 -HB- Series – CANopen | R-Series RH CANopen |
| MSI-H Start/Stop | BTL5 -HB- Series – Digital | E-Series EH Start/Stop |
| MSI-H CANopen | BTL5 -K- Series – CANopen | R-Series RH CANopen |
| MSI-H Start/Stop | BTL5 -K- Series – Digital | E-Series EH Start/Stop |
| MSI-H DeviceNet | R-Series RH DeviceNet | |
| MSI-H DeviceNet | R-Series RP DeviceNet |


Related products
MSI-201 542-2 Position magnet
Price on request
MSI-BAM013L Position magnet
Price on request
MSI-MT0162 Position magnet
Price on request
MSI-400 533 Position magnet
Price on request
MSI-253 572-2 Position magnet
Price on request
MSI-400 333 Non-magnetic spacer
Price on request
MSI-400 833 Non-magnetic spacer
Price on request
MSI-400 325 Non-magnetic spacer
Price on request
MSI-400 825 Non-magnetic spacer
Price on request
Downloads
Technical Documentation
Technical drawing
Certificates
Inquiry Form
Contact a specialist