MSI-D Series Linear Position Sensor with EtherCAT Output

Rod-style, high-precision, absolute, non-contact magnetostrictive position sensor with remote electronics, featuring a measuring range from 25 to 3800 mm.
Position measurement is performed using ring-type position magnets that move along the waveguide without physical contact.
The sensor flange is made of high-quality stainless steel and is designed for long-term industrial operation.

Price on request

CONFIGURATOR
CONTACT US

Design features

  • The modular sensor design provides advantages for installation in confined spaces and simplifies service and maintenance of the MSI-D series sensors.
  • The sensor consists of two separate parts: the electronics and the waveguide are spaced by up to 350 mm with bottom connection and up to 600 mm with side connection.
  • Compatible with all Temposonics position magnets and selected BALLUFF magnets
  • Zero position offset of 50 mm, 30 mm, or customer-specific value
  • Absolute linear measurement (output signals proportional to magnet displacement)
  • LED status indicator for diagnostics
  • High accuracy: resolution up to 1 µm
  • Measuring length from 25 to 3800 mm (1 mm increments)
  • Linearity < 0.01 %
  • Repeatability < 0.001 %
  • Operating temperature up to +85 °C
  • Optional operating pressure up to 800 bar
  • Protection class IP67

Configurator

MSI-D

.

_

_

.

_

.

_

.

_

.

E

_

_

_

MSI-D Series Linear Position Sensor with EtherCAT Output, order code:

Scope of delivery

THE SCOPE OF SUPPLY INCLUDES:

Linear position sensor

Certificate of Conformity

Manual

Warranty card

Mating connectors and magnets for the sensor must be ordered separately!

Product ordering code

TECHNICAL REQUIREMENTS FOR ORDER PLACEMENT

1

2

3

4

5

6

7

8

9*

MSI-D

.

1

D

3

S

.

0

5

0

0

.

T

.

D56

.

U

4

0

1

1

Series:

MSI-D - Rod-style with detached electronics

2

Flange type:

1 - Embeddable flange Ø 34,5 mm

2 - M18x1.5 flange (standard)

3 - Embeddable flange Ø 26,92 mm

3

D1S - Side connection. Polyurethane cable, 250 mm long

D2S - Side connection. Polyurethane cable, 400 mm long

D3S - Side connection. Polyurethane cable, 600 mm long

R4B - Bottom connection. Single wires with a flat connector, length 170 mm

R5B - Bottom connection. Single wires with a flat connector, length 230 mm

R6B - Bottom connection. Single wires with a flat connector, length 350 mm

4

Measuring range:

0025...3800 mm, 1 mm step

Other lengths available on request

5

Zero point:

T - 50 mm

B - 30 mm

6

Подключение:

D56 - Interface: 5-pin male and female connector, M12-D

     Power supply: 4-pin male connector, M8

7

Output signal:

E - EtherCAT

8

Position measurement type:

102 - multi-position measurement, 2–8 positions

101 - single-position measurement (standard)

9*

Number of positions:

Z02 - 2 positions

...

Z08 - 8 positions

*Only for E102.

Technical specifications

OUTPUT PARAMETERS

Measured value

Position

Operating range, L

25 — 3800 mm, 1 mm step

Displacement speed

Any

Update rate

0.5 ms up to 1200 mm; 1.0 ms up to 2400 mm; 2.0 ms up to 3800 mm

Status diagnostics

LEDs next to the connector

INTERFACE

Digital interface

EtherCAT Bus

Data transfer protocol

100 Base-Tx, Fast Ethernet

Number of magnets

1-8

Max cable length

Cable length: <100 m

Transmission speed: 100 Mbps

Measurements were performed using a Cat-5 cable

POSITION MEASUREMENT ACCURACY

Linearity

< ± 0.01 % F.S. (minimum ± 40 µm)

Repeatability

< ± 0.001 % F.S. (minimum ± 2.5 µm)

OPERATING CONDITIONS

Operating temperature

-40 °C…+85 °C

Rated pressure

350 bar, 600 bar peak (optional 800 bar)

Humidity

90 % rel. humidity, no condensation

Ingress protection

IP65, IP67 at cable outlet

MATERIALS

Sensor electronics housing

Aluminum, plastic

Sensor rod

Stainless steel ASTM A269-13 / TP304l (10x1.5)

Flange

Stainless steel 08Х18Н10 / AISI 304

MOUNTING

Mounting position

Any orientation. For horizontal installation of sensors with an operating range exceeding 1000 mm, the rod must be supported or fixed at the end

Flange parameters

Flange thread M18×1.5 or 3/4"-16 UNF

Position magnet mounting

Mounting hardware and screws made of non-magnetic material

ELECTRICAL CONNECTION

Operating voltage

24 (- 15 / +20 %) V DC

Reverse polarity protection

up to –30 V DC

Overvoltage protection

up to 36 V DC

Current consumption

50…140 mA (depending on sensor length)

Insulation resistance

500 V DC (between sensor housing and 0 V DC)

STANDARDS, EMC TESTS

Shock test

100 g, single shock according to IEC 60068-2-7

Vibration test

15 g / 10–2000 Hz according to IEC 60068-2-6

EMC tests

GOST R IEC 61326-1-2014

Connection: D56 connector

BUS INPUT PORT №1

CONTACT

FUNCTION

M12 socket, D-coding

(view from sensor side)

1

Tx (+) (bus)

2

Rx (+) (bus)

3

Tx (-) (bus)

4

Rx (-) (bus)

BUS OUTPUT PORT №2

CONTACT

FUNCTION

M12 socket, D-coding

(view from sensor side)

1

Tx (+) (bus)

2

Rx (+) (bus)

3

Tx (-) (bus)

4

Rx (-) (bus)

SENSOR POWER SUPPLY

CONTACT

FUNCTION

M8 plug

(view from sensor side)

1

+24 V DC (−15 / +20 %)

2

Not used

3

0 V DC (power supply reference)

4

Not used

Installation recommendations

ELECTRONICS CONNECTION OPTIONS

BOTTOM CONNECTION

SIDE CONNECTION

CONNECTION TYPE No. 1

Embeddable flange Ø 34,5 mm, side connection:

Embeddable flange Ø 34,5 mm, bottom connection:

Installation recommendations:

CONNECTION TYPE No. 2

M18x1.5 flange (standard) for bottom electronics connection

M18x1.5 flange (standard) for side electronics connection

Installation recommendations:

CONNECTION TYPE No.3

Embeddable flange Ø26.92 mm for bottom electronics connection

Embeddable flange Ø26.92 mm for side electronics connection

Installation recommendations:

EXAMPLE OF SENSOR INSTALLATION IN A HYDRAULIC CYLINDER

Embeddable Ø29,92 mm with bottom connection

M18x1.5 flange (standard) for bottom electronics connection

* The zero position is specified when ordering the sensor and can be set at a distance of 30 mm or 50 mm

* Non-magnetic spacer No. 1 is required only when the zero position is set at 30 mm from the linear position sensor flange and the sensor sleeve is made of magnetic material.

Interface

EtherCAT (Ethernet for Control Automation Technology) is a high-performance industrial Ethernet protocol standardized under IEC 61158. The protocol supports data transmission rates of 100 Mbit/s and 1 Gbit/s. EtherCAT offers high flexibility in network topology: networks can be built in line, star, ring, tree, or hybrid configurations. No additional Ethernet switches are required for network implementation, which simplifies deployment and reduces costs. Within a single network segment, up to 65,535 devices can be connected, including sensors, servo drives, and programmable logic controllers (PLCs).

Device configuration is performed via ESI (EtherCAT Slave Information) XML files or through a web interface, ensuring convenient integration into existing automation systems.

Synchronization:

  • Hard Real-Time  hard real-time mode providing a data update cycle of no more than 100 µs.
  • Distributed Clocks(DC) — enables device synchronization with nanosecond-level accuracy, which is essential for coordinating complex motion systems.

Compatibility with other standards:

  • CoE – CANopen over EtherCAT –enables integration with CANopen devices.
  • SoE – SERCOS over EtherCAT – enables integration with SERCOS systems.
  • EoE – Ethernet over EtherCAT – allows transmission of TCP/IP traffic within an EtherCAT network.

A key feature of EtherCAT is “on-the-fly” data processing: each network node processes the Ethernet frame as it passes through, without buffering. This significantly reduces latency and increases bandwidth efficiency, achieving up to 90% effective payload utilization of the Ethernet frame. The protocol is highly scalable and suitable for systems of any complexity — from local installations to distributed networks with thousands of devices.

EtherCAT Frame Format

 

Multi-position measurement

Connection example

Status diagnostics

LED LOCATION

GREEN

RED

STATUS

Off

Off

The sensor is not connected to the power supply or is faulty

On

Off

Normal operation

On

On

Position magnet is missing or an incorrect number of position magnets is present

Interchangeability

MSIBalluffTemposonics
MSI-H EtherCATBTL7 -Y/Z- Series – EtherCATR-Series V RH5 EtherCAT
MSI-H ProfinetBTL7 -Y/Z- Series - ProfinetR-Series V RH5 Profinet
MSI-H AnalogBTL7 -Y/Z- Series - Analog voltageR-Series V RH5 Analog
MSI-H SSIBTL7 -Y/Z- Series – SSIR-Series V RH5 SSI
MSI-H AnalogBTL7 -Y/Z- Series - Analog currentR-Series V RH5 Analog
MSI-H SSIBTL7 -A/B- Series – SSIR-Series V RH5 SSI
MSI-H EtherCATBTL7 -A/B- Series – EtherCATR-Series V RH5 EtherCAT
MSI-H ProfinetBTL7 -A/B- Series – ProfinetR-Series V RH5 Profinet
MSI-H AnalogBTL7 -A/B- Series - Analog voltageR-Series V RH5 Analog
MSI-H AnalogBTL7 -A/B- Series - Analog currentR-Series V RH5 Analog
MSI-H CANopenBTL5 -Y/Z- Series – CANopenR-Series RH CANopen
MSI-H ProfinetBTL5 -Y/Z- Series – ProfibusR-Series V RH5 Profinet
MSI-H CANopenBTL5 -A/B- Series - CANopenR-Series RH CANopen
MSI-H ProfibusBTL5 -A/B- Series - ProfibusR-Series RH Profibus
MSI-H Start/StopBTL7 -BE/BF- Serie - DigitalE-Series EH Start/Stop
MSI-H SSIBTL7 -BE/BF- Serie – SSIR-Series V RH5 SSI
MSI-H Start/StopBTL7 -ZE/ZF- Serie – DigitalE-Series EH Start/Stop
MSI-H SSIBTL7 -ZE/ZF- Serie – SSIR-Series V RH5 SSI
MSI-H Start/StopBTL7 -CE- Serie – DigitalE-Series EH Start/Stop
MSI-H SSIBTL7 -CE- Serie – SSIR-Series V RH5 SSI
MSI-H Start/StopBTL7 -CD- Series – DigitalE-Series EH Start/Stop
MSI-H AnalogBTL7 -CD- Series - Analog voltageR-Series V RH5 Analog
MSI-H SSIBTL7 -CD- Series – SSIR-Series V RH5 SSI
MSI-H AnalogBTL7 -CD- Series - Analog currentR-Series V RH5 Analog
MSI-H CANopenBTL5 -W- Series – CANopenR-Series RH CANopen
MSI-H CANopenBTL5 -WB- Series - CANopenR-Series RH CANopen
MSI-H Start/StopBTL5 -WB- Series – DigitalE-Series EH Start/Stop
MSI-H Start/StopBTL5 -W- Series – DigitalE-Series EH Start/Stop
MSI-H CANopenBTL5 -HB- Series – CANopenR-Series RH CANopen
MSI-H Start/StopBTL5 -HB- Series – DigitalE-Series EH Start/Stop
MSI-H CANopenBTL5 -K- Series – CANopenR-Series RH CANopen
MSI-H Start/StopBTL5 -K- Series – DigitalE-Series EH Start/Stop
MSI-H DeviceNetR-Series RH DeviceNet
MSI-H DeviceNetR-Series RP DeviceNet

Downloads

Technical Documentation

v.2.2 – 20.11.25

PDF

22 МБ

22 МБ

01.04.2025

PDF

11 МБ

11 МБ

Certificates
Software

Contact a specialist

    © MSISU 2026. All rights reserved