MSI-951 029 Start/Stop to Profibus Interface Converter (4 Channels)

Start/Stop to Profibus Interface Converter (4 Channels)
Manual device address configuration on the unit
Manual bus terminator switch on the unit
Connection of Start/Stop sensors via 6-wire interface
Compatible with MTS Sensors GSD file
Direct replacement for EB342-0101

Price on request

CONFIGURATOR
GET EXPERT CONSULTATION

Available Settings

 

ATTENTION!
For proper operation, the device must be configured in accordance with the information specified on the sensor’s factory label.

Configurator

MSI-951 029

_

MSI-951 029 Start/Stop to Profibus Interface Converter (4 Channels), order code:

Scope of Supply

THE SCOPE OF SUPPLY INCLUDES:

Start/Stop to Profibus Interface Converter, MSI-951 029 (1 pc)

Power supply unit 220 VAC → 24 VDC (1 pc)

Sensor connection cable (depending on the selected configuration) (1 pc)

User manual

Order Code

ORDER CODE

1

2

MSI-951 029

-

D60

1

Series:

MSI-951 029 - Start/Stop to Profibus interface converter

2

Connector type:

D60 - for connection of sensors with 7-pin M16 male connector

H01 - for connection of sensors with cable outlet

D60/H01 - for connection of sensors of all modifications

Technical Specifications

GENERAL INFORMATION

Housing dimensions

145х90х40 mm (WхHхL)

Mounting

DIN rail (EN 50022)

Screw terminals 1.5 mm²

4 terminal blocks with 6 contacts each, 2 terminal blocks with 4 contacts each

Housing material

ABS

Operating voltage

+24 VDC (- 15 / +20 %)

Output voltage

+24 VDC (max. 750 mA)

Operating temperature

0 ... +75° С

Ingress protection

Housing: IP40

Terminals: IP20

Weight

250 g

INTERFACE

Input:

Number of channels

Up to 4 sensors with Start/Stop output

4 × Start/Stop signal RS-422

Cable length

up to 120 m

Short-circuit protection

Yes

Output:

Output signal

RS-485, Profibus-DP

Protocol

EN 50170 (DIN 19245)

AVAILABLE SETTINGS

Transmission rate

9600 … 12 000 kbit/s

Position data

24 bits per position value

Format: Intel / Motorola

Maximum measuring range: up to 7600 mm

Resolution

Minimum: 0,005 mm

Update rate (cycle time)

Measuring Range (mm) / Cycle Time (ms)

up to 400 / 0,75

up to 1500 / 1,00

up to 3100 / 1,50

up to 4300 / 2,00

up to 5700 / 2,50

up to 6900 / 3,00

> 6900 / 3,50

ADDITIONAL FEATURES

Configuration tool

GSD files

Quick sensor connection

Yes

Device Description

The MSI-951 029 is an industrial interface converter designed to connect up to four linear position sensors with Start/Stop output to a Profibus-DP network. The device ensures high-precision transmission of position data over an RS-485 interface supporting the Profibus-DP protocol and is intended for use in automated control and monitoring systems.

The converter can simultaneously process signals from up to four sensors, ensuring stable operation, high resolution, and flexible configuration via GSD files.

Terminal Layout

Status Diagnostics

1. Sensor Status Indicator (Green)

  • Normal operation (sensor transmitting position data): The LED is continuously illuminated in green.
  • No signal / Fault: The LED is off. This indicates one of the following conditions:
    • The position magnet is outside the sensor measuring range.
    • The sensor is not connected to the unit or is damaged.

2. Power Indicator

  • Power ON: The LED is illuminated (typically red or green depending on the model), indicating that the unit is receiving power.
  • Power OFF: The LED is OFF.