MSI-951 029 Start/Stop to Profibus Interface Converter (4 Channels)
Start/Stop to Profibus Interface Converter (4 Channels)
Manual device address configuration on the unit
Manual bus terminator switch on the unit
Connection of Start/Stop sensors via 6-wire interface
Compatible with MTS Sensors GSD file
Direct replacement for EB342-0101
Price on request
Available Settings
ATTENTION!
For proper operation, the device must be configured in accordance with the information specified on the sensor’s factory label.
Configurator
MSI-951 029
_
MSI-951 029 Start/Stop to Profibus Interface Converter (4 Channels), order code:
Scope of Supply
THE SCOPE OF SUPPLY INCLUDES: | |
Start/Stop to Profibus Interface Converter, MSI-951 029 (1 pc) | |
Power supply unit 220 VAC → 24 VDC (1 pc) | |
Sensor connection cable (depending on the selected configuration) (1 pc) | |
User manual | |
Order Code
ORDER CODE | ||
1 | 2 | |
MSI-951 029 | - | D60 |
1 | Series: MSI-951 029 - Start/Stop to Profibus interface converter | |
2 | Connector type: D60 - for connection of sensors with 7-pin M16 male connector H01 - for connection of sensors with cable outlet D60/H01 - for connection of sensors of all modifications | |
Technical Specifications
GENERAL INFORMATION | |
Housing dimensions | 145х90х40 mm (WхHхL) |
Mounting | DIN rail (EN 50022) |
Screw terminals 1.5 mm² | 4 terminal blocks with 6 contacts each, 2 terminal blocks with 4 contacts each |
Housing material | ABS |
Operating voltage | +24 VDC (- 15 / +20 %) |
Output voltage | +24 VDC (max. 750 mA) |
Operating temperature | 0 ... +75° С |
Ingress protection | Housing: IP40 Terminals: IP20 |
Weight | 250 g |
INTERFACE | |
Input: | |
Number of channels | Up to 4 sensors with Start/Stop output 4 × Start/Stop signal RS-422 |
Cable length | up to 120 m |
Short-circuit protection | Yes |
Output: | |
Output signal | RS-485, Profibus-DP |
Protocol | EN 50170 (DIN 19245) |
AVAILABLE SETTINGS | |
Transmission rate | 9600 … 12 000 kbit/s |
Position data | 24 bits per position value Format: Intel / Motorola Maximum measuring range: up to 7600 mm |
Resolution | Minimum: 0,005 mm |
Update rate (cycle time) | Measuring Range (mm) / Cycle Time (ms) up to 400 / 0,75 up to 1500 / 1,00 up to 3100 / 1,50 up to 4300 / 2,00 up to 5700 / 2,50 up to 6900 / 3,00 > 6900 / 3,50 |
ADDITIONAL FEATURES | |
Configuration tool | GSD files |
Quick sensor connection | Yes |
Device Description
The MSI-951 029 is an industrial interface converter designed to connect up to four linear position sensors with Start/Stop output to a Profibus-DP network. The device ensures high-precision transmission of position data over an RS-485 interface supporting the Profibus-DP protocol and is intended for use in automated control and monitoring systems.
The converter can simultaneously process signals from up to four sensors, ensuring stable operation, high resolution, and flexible configuration via GSD files.
Terminal Layout

Status Diagnostics
Downloads