MSI-HS Series Linear Position Sensor with Start/Stop Output
Rod-type, high-precision, absolute, contactless, magnetostrictive sensor with an operating range from 25 to 3800 mm.
Position measurements are performed using ring-shaped position magnets that move along the waveguide without physical contact.
The sensor flange is made of high-quality stainless steel and is designed for long-term operation.
Price on request
Design features
- Compact design
- Absolute linear measurement (output signals proportional to the displacement of the position magnet)
- High accuracy: resolution up to 1 μm
- Measuring range from 25 to 3800 mm, adjustable in 1 mm increments
- Linearity < 0.01%
- Repeatability < 0.001%
- Operating temperature up to 75 °C
- IP68 protection rating
- Designed for use in harsh environments
Configurator
MSI-HS
.
M
.
_
.
T
.
_
_
.
R01
MSI-HS Series Linear Position Sensor with Start/Stop Output, order code:
Scope of delivery
THE DELIVERY SET INCLUDES: | |
Linear position sensor | |
Certificate of Conformity | |
Documentation (datasheet / manual) | |
Warranty card | |
Mating connectors and magnets for the sensor must be ordered separately! | |
Sensor calibration with entry in ARSHIN is charged separately! | |
Product ordering code
TECHNICAL REQUIREMENTS FOR ORDER PLACEMENT | |||||||||||||||
1 | 2 | 3 | 4 | 5 | 6 | ||||||||||
MSI-HS | . | M | . | 0 | 5 | 0 | 0 | . | T | . | D60 | . | R | 0 | 1 |
1 | Series: MSI-HS - Rod-type | ||||||||||||||
2 | Flange type: M - M18 × 1.5, rod Ø 10 mm G - Plug-in flange 45F7, rod Ø 10 mm | ||||||||||||||
3 | Operating range*: 0025...3800 mm, 1 mm step Other lengths available on request | ||||||||||||||
4 | Zero point*: T - 50 mm B - 27 mm | ||||||||||||||
5 | Connection: D60 - 6-pin male connector, M16 R02 - PVC cable without connector, 2 m; option: R01...R20 (1...20 m) H02 - PUR cable without connector, 2 m; option: H01...H20 (1...20 m) | ||||||||||||||
6 | Output signal: R01 - Start/Stop | ||||||||||||||
*Measuring range is programmable | |||||||||||||||
Technical specifications
OUTPUT PARAMETERS | |
Measured value | Position |
Operating range, L | 25 — 3800 mm, 5 mm step |
Displacement speed | Any |
Update rate | 0.5 ms up to 1200 mm; 1.0 ms up to 2400 mm; 2.0 ms up to 3800 mm |
INTERFACE | |
Digital interface | RS-485/422 |
Data transfer protocol | Start/Stop |
Number of position magnets | 1 |
Max cable length | For stable operation, it is recommended to use a cable no longer than 50 meters |
POSITION MEASUREMENT ACCURACY | |
Linearity | < ± 0.01 % F.S. (minimum ± 40 µm) |
Repeatability | < ± 0.001 % F.S. (minimum ± 2.5 µm) |
VELOCITY MEASUREMENT ACCURACY | |
Resolution | 0.1 mm/s |
Linearity error | < 0.5 % |
OPERATING CONDITIONS | |
Operating temperature | -40 °C…+105 °C |
Rated pressure | 350 bar, 600 bar peak (optionally 800 bar) |
Humidity | 90 % rel. humidity, no condensation |
Ingress protection | IP68, IP67 (with mated connector) |
MATERIAL | |
Sensor electronics housing | Stainless steel 08Х18Н10 / AISI 304 |
Sensor rod | Stainless steel ASTM A269-13 / TP304l (10x1.5) |
Flange | Stainless steel 08Х18Н10 / AISI 304 |
INSTALLATION | |
Mounting position | Any. When the sensor is installed horizontally with a measuring range exceeding 1000 mm, its rod must be supported or secured at the end. |
Flange parameters | Flange thread M18×1.5 |
Position magnet mounting | Mounting hardware and screws made of non-magnetic material |
ELECTRICAL CONNECTION | |
Operating voltage | For L < 2500: +12/24 V DC (−10 % / +20 %) For L > 2500: +24 V DC (−15 % / +20 %) |
Reverse polarity protection | up to −30 V DC |
Overvoltage protection | up to 36 V DC |
Supply current | 50…140 mA (depending on sensor length) |
Insulation resistance | 500 V DC (between sensor housing and 0 V DC) |
STANDARDS, EMC TESTS | |
Shock test | 100 g — single shock according to IEC 60068-2-7 |
Vibration test | 15 g / 10–2000 Hz according to IEC 60068-2-6 |
EMC tests | GOST R IEC 61326-1-2014 |
Connection: cable outlet
CABLE | D60 | FUNCTION | |
Black | 1 | Stop (-) | |
White | 2 | Stop (+) | |
Yellow | 3 | Start (+) | |
Green | 4 | Start (-) | |
Red | 5 | +24 V DC (−15 % / +20 %) | |
Blue | 6 | 0 V DC (power source) | |
For stable operation, it is recommended to use a cable no longer than 35 meters.
Connection: D60 connector
PIN ASSIGNMENT | PIN | FUNCTION |
![]() M16 male connector (view from the sensor side) | 1 | Stop (-) |
2 | Stop (+) | |
3 | Start (+) | |
4 | Start (-) | |
5 | +24 V DC (−15 % / +20 %) | |
6 | 0 V DC (power supply) |
Interface
DIGITAL INTERFACE START/STOP |
![]() The "Ready" signal generation indicates a new measurement cycle and occurs in the Start/Stop module simultaneously with the "Start" signal. After the "Start" signal is generated, the Start/Stop module switches to line listening mode and waits for the "Stop" signal from the linear position sensor. The time difference (dt) between the "Start" and "Stop" signals is directly proportional to the position of the position magnet. |
Connection example
CONNECTION DIAGRAM FOR THE DEVICE (Duplex) |
![]() |
CONNECTION DIAGRAM FOR THE DEVICE (Half-Duplex) |
Interchangeability
Downloads
Technical Documentation
Certificates
Inquiry Form