The MSI-H series is a rod-type, high-precision, absolute, non-contact magnetostrictive linear position sensor with a measuring range from 25 to 6000 mm.

Position measurement is performed using ring-type position magnets that move along the waveguide without physical contact. The sensor flange is made of high-quality stainless steel and designed for long-term operation in demanding industrial environments.

Price on request

CONFIGURATOR
CONTACT US

Design Features

  • Adjustable node address and zero position
  • Modular design allows fast replacement without depressurizing the hydraulic circuit
  • Compatible with all Temposonics position magnets and selected BALLUFF magnets
  • Zero position offset of 50 mm, 30 mm, or customer-specific value
  • Measurement start point from the sensor housing by default
  • Absolute linear measurement (output signals proportional to magnet displacement)
  • LED status indicator for diagnostics
  • High accuracy: resolution up to 5 µm
  • Measuring length from 25 to 6000 mm (1 mm increments)
  • Linearity < 0.01 % F.S.
  • Repeatability < 0.001 % F.S.
  • Operating temperature up to +85 °C
  • Optional operating pressure up to 800 bar
  • Protection class IP67

Configurator

MSI-H

.

_

.

_

.

_

.

_

.

U

_

_

_

MSI-H Series Magnetostrictive Linear Position Sensor with Profinet Output, order code:

Scope of delivery

THE SCOPE OF SUPPLY INCLUDES:

Linear position sensor

Certificate of Conformity

Manual

Warranty card

Mating connectors and magnets for the sensor must be ordered separately!

Product ordering code

TECHNICAL REQUIREMENTS FOR ORDER PLACEMENT

1

2

3

4

5

6

7

8*

9*

MSI-H

.

S

.

0

5

0

0

.

T

.

D56

.

U

4

0

1

1

Series:

MSI-H - Rod-Type

2

Flange Type:

M – M18 × 1.5, rod Ø10 mm

S – 3/4”-16 UNF, rod Ø10 mm

R – M18 × 1.5 with M4 thread on rod end, Ø10 mm

Z – 3/4”-16 UNF with M4 thread on rod end, Ø10 mm

T – 3/4”-16 UNF with raised face, Ø10 mm

V – M18 × 1.5 with FKM seal, Ø10 mm

U – 3/4”-16 UNF with raised face, FKM seal, Ø10 mm

H – 3/4”-16 UNF, FKM seal, Ø10 mm

L – 3/4”-16 UNF, rod Ø7 mm

K – M18 × 1.5, rod Ø7 mm

4

Measuring Range:

0025...6000 mm, 1 mm step

Other lengths available on request

5

Zero Point:

T - 50 mm

B - 30 mm

6

Connection:

D56 - Interface: 2 × 5-pin M12-D female; Power: 4-pin M8 male

D58 - Interface: 2 × 5-pin M12-D female; Power: 4-pin M12-A male

7

Output Signal:

U - Profinet RT&IRT

8

Position measurement mode:

402 - multi-position measurement (2–8 positions)

401 - single-position measurement (standard)

9*

Node Address: 1...125 ( Factory setting 125)

10*

Number of Magnets:

Z02 - 2 positions

...

Z08 - 8 positions

*Only for C207

Technical data

OUTPUT PARAMETERS

Measured quantity

Position

Operating range, L

25 — 6000 mm, 1 mm step

Velocity

0.025 - 10 m/s

Movement speed

Any

Cycle time

0.5 ms up to 1200 mm; 1.0 ms up to 2400 mm;

2.0 ms up to 4500 mm; 3.0 ms up to 6000 mm

Status diagnostics

LEDs next to the connector

INTERFACE

Digital interface

Шина Profinet RT / IRT версия 2.3

Data protocols

Encoder Profile 4.1

Number of magnet

1-8

Max cable length

Сable length, m <100

Transmission Speed, Mbit/s 100

Измерения проводились с использованием кабеля Cat-5

POSITION MEASUREMENT ACCURACY

Resolution

1…100 µm (selectable)

Linearity deviation

L <= 500 mm: ± 50 µm

L > 500 mm: ± 0.01 % F.S.

Repeatability

< ± 0.001 % F.S. (minimum ± 2.5 µm)

OPERATING CONDITIONS

Operating temperature

-40 °C…+85 °C

Rated pressure

350 bar, 600 bar peak (optional 800 bar)

Humidity

90 % rel. humidity, no condensation

Ingress protection 

IP65, IP67 at cable outletat cable outlet

MATERIALS

Sensor electronics housing

Anodized aluminum, plastic

Sensor rod

Stainless steel ASTM A269-13 / TP304l (10x1.5)

Flange

Stainless steel 08Х18Н10 / AISI 304

MOUNTING

Mounting position

Any orientation. For horizontal installation of sensors with an operating range exceeding 1000 mm, the rod must be supported or fixed at the end

Flange parameters

Flange thread M18х1.5, M22 x 1.5 or 3/4" - 16 UNF

Position magnet attachment

Mounting hardware and screws made of non-magnetic material

ELECTRICAL CONNECTION

Operating voltage

24 V DC (–15 % / +20 %)

Reverse polarity protection

up to –30 V DC

Overvoltage protection

up to 36 V DC

Current consumption

50…140 mA (depending on sensor length)

Insulation resistance

500 V DC (between sensor housing and 0 V DC)

STANDARDS, EMC TESTS

Shock test

100 g, single shock according to IEC 60068-2-7

Vibration test

15 g / 10–2000 Hz according to IEC 60068-2-6

EMC Tests

GOST R IEC 61326-1-2014

Connector wiring: D56

BUS INPUT PORT No. 1

PIN

OUTPUT

M12 female, D-coded

(view from sensor side)

1

Tx (+) (bus)

2

Rx (+) (bus)

3

Tx (-) (bus)

4

Rx (-) (bus)

BUS INPUT PORT No. 2

PIN

OUTPUT

M12 female, D-coded

(view from sensor side)

1

Tx (+) (bus)

2

Rx (+) (bus)

3

Tx (-) (bus)

4

Rx (-) (bus)

POWER SUPPLY

PIN

OUTPUT

M8 male

(view from sensor side)

1

+24 VDC (−15/+20 %)

2

-

3

DC Ground (0 V)

4

-

Connector wiring: D58

PIN CONFIGURATION

PORT №1

PIN

OUTPUT

M12 female, D-coded (sensor side view

1

Tx (+) (bus)

2

Rx (+) (bus)

3

Tx (-) (bus)

4

Rx (-) (bus)

PIN CONFIGURATION

PORT №1

PIN

OUTPUT

M12 female, D-coded (sensor side view

1

Tx (+) (bus)

2

Rx (+) (bus)

3

Tx (-) (bus)

4

Rx (-) (bus)

POWER SUPPLY

PIN

OUTPUT

M12 male, A-coded (sensor side view

1

+24 VDC (−15/+20 %)

2

-

3

DC Ground (0 V)

4

-

Interface

The sensor complies with all requirements of the ProfiNET standard (IEC 61158), providing high-speed data transmission over an industrial Ethernet network. All measurements performed by the sensor are absolute and are transmitted at speeds of up to 100 Mbit/s.

The ProfiNET bus allows up to 256 devices to be connected within a single network, ensuring system flexibility and scalability. Various network topologies are supported, including star, ring, and line. Sensor parameters are loaded into the system using a GSDML file.

Sensor operating modes:

Real-Time (RT) mode:

  • Provides data transmission with minimal latency.
  • Suitable for applications that do not require strict synchronization.

Isochronous Real-Time (IRT) mode:

  • Provides precise synchronization of devices within the network.
  • Used in applications with high requirements for timing performance.

Multi-position measurement

MULTI-POSITION MEASUREMENT

Data Exchange

When measuring with multiple magnets, 1 byte of status data and 3 bytes of position data are transmitted per cycle for each magnet.

The status byte contains: an error bit, and the number of positions in the current measurement.

U401 — Single-magnet measurement (standard)

U402 — Multi-magnet measurement, 2 to 8 magnets

Simultaneous measurement with up to 8 magnets is supported; the minimum distance between magnets is 76 mm.

Connection example

CONNECTION EXAMPLE

Status diagnostics


LED DIAGNOSTICS


GREEN

RED

STATUS

Off

Off

No power supply or sensor fault

On

Off

Normal operation

On

On

No position magnet or incorrect number of magnets

Flashing

Off

Programming mode ( analog output only)

Interchangeability

MSIBalluffTemposonics
MSI-H EtherCATBTL7 -Y/Z- Series – EtherCATR-Series V RH5 EtherCAT
MSI-H ProfinetBTL7 -Y/Z- Series - ProfinetR-Series V RH5 Profinet
MSI-H AnalogBTL7 -Y/Z- Series - Analog voltageR-Series V RH5 Analog
MSI-H SSIBTL7 -Y/Z- Series – SSIR-Series V RH5 SSI
MSI-H AnalogBTL7 -Y/Z- Series - Analog currentR-Series V RH5 Analog
MSI-H SSIBTL7 -A/B- Series – SSIR-Series V RH5 SSI
MSI-H EtherCATBTL7 -A/B- Series – EtherCATR-Series V RH5 EtherCAT
MSI-H ProfinetBTL7 -A/B- Series – ProfinetR-Series V RH5 Profinet
MSI-H AnalogBTL7 -A/B- Series - Analog voltageR-Series V RH5 Analog
MSI-H AnalogBTL7 -A/B- Series - Analog currentR-Series V RH5 Analog
MSI-H CANopenBTL5 -Y/Z- Series – CANopenR-Series RH CANopen
MSI-H ProfinetBTL5 -Y/Z- Series – ProfibusR-Series V RH5 Profinet
MSI-H CANopenBTL5 -A/B- Series - CANopenR-Series RH CANopen
MSI-H ProfibusBTL5 -A/B- Series - ProfibusR-Series RH Profibus
MSI-H Start/StopBTL7 -BE/BF- Serie - DigitalE-Series EH Start/Stop
MSI-H SSIBTL7 -BE/BF- Serie – SSIR-Series V RH5 SSI
MSI-H Start/StopBTL7 -ZE/ZF- Serie – DigitalE-Series EH Start/Stop
MSI-H SSIBTL7 -ZE/ZF- Serie – SSIR-Series V RH5 SSI
MSI-H Start/StopBTL7 -CE- Serie – DigitalE-Series EH Start/Stop
MSI-H SSIBTL7 -CE- Serie – SSIR-Series V RH5 SSI
MSI-H Start/StopBTL7 -CD- Series – DigitalE-Series EH Start/Stop
MSI-H AnalogBTL7 -CD- Series - Analog voltageR-Series V RH5 Analog
MSI-H SSIBTL7 -CD- Series – SSIR-Series V RH5 SSI
MSI-H AnalogBTL7 -CD- Series - Analog currentR-Series V RH5 Analog
MSI-H CANopenBTL5 -W- Series – CANopenR-Series RH CANopen
MSI-H CANopenBTL5 -WB- Series - CANopenR-Series RH CANopen
MSI-H Start/StopBTL5 -WB- Series – DigitalE-Series EH Start/Stop
MSI-H Start/StopBTL5 -W- Series – DigitalE-Series EH Start/Stop
MSI-H CANopenBTL5 -HB- Series – CANopenR-Series RH CANopen
MSI-H Start/StopBTL5 -HB- Series – DigitalE-Series EH Start/Stop
MSI-H CANopenBTL5 -K- Series – CANopenR-Series RH CANopen
MSI-H Start/StopBTL5 -K- Series – DigitalE-Series EH Start/Stop
MSI-H DeviceNetR-Series RH DeviceNet
MSI-H DeviceNetR-Series RP DeviceNet

Downloads

Technical Documentation

v.2.2 – 20.11.25

PDF

43 МБ

43 МБ

01.04.2025

PDF

33 МБ

33 МБ

Certificates

Contact us

    © MSISU 2026. All rights reserved