MSI-D Series Magnetostrictive Linear Position Sensor with CAN Output

Rod-style, high-precision, absolute, non-contact magnetostrictive position sensor with remote electronics, featuring a measuring range from 25 to 3800 mm. Position measurement is performed using ring-type position magnets that move along the waveguide without physical contact. The sensor flange is made of high-quality stainless steel and is designed for long-term industrial operation.

Price on request

CONFIGURATOR
CONTACT US

Design Features

  • Rod-style, high-precision, absolute, non-contact magnetostrictive position sensor with remote electronics, featuring a measuring range from 25 to 3800 mm.
  • Position measurement is performed using ring-type position magnets that move along the waveguide without physical contact.
  • The sensor flange is made of high-quality stainless steel and is designed for long-term industrial operation.
  • The modular sensor design provides advantages for installation in confined spaces and simplifies service and maintenance of the MSI-D series sensors.
  • The sensor consists of two separate parts: the electronics and the waveguide are spaced by up to 350 mm with bottom connection and up to 600 mm with side connection.
  • The sensor is compatible with all Temposonics position magnets and with selected magnets from BALLUFF.
  • Zero position can be set at 50 mm or 30 mm, or to a custom value upon request.
  • The sensor provides absolute linear measurement, where the output signals are proportional to the displacement of the position magnet.
  • An LED indicator is provided for sensor diagnostics.
  • The sensor delivers high accuracy with resolution up to 1 μm.
  • Measuring length is available from 25 to 3800 mm with 1 mm increments.
  • Linearity: < 0.01 %
  • Repeatability: < 0.001 %
  • Operating temperature: up to 85 °C
  • Protection class: IP67

Configurator

MSI-D

.

_

_

.

_

.

_

.

_

.

C

_

_

_

_

_

MSI-D Series Magnetostrictive Linear Position Sensor with CAN Output, order code:

Scope of delivery

THE SCOPE OF SUPPLY INCLUDES:

Linear position sensor

Certificate of Conformity

Manual

Warranty card

Mating connectors and magnets for the sensor must be ordered separately!

Product ordering code

TECHNICAL REQUIREMENTS FOR ORDER PLACEMENT

1

2

3

4

5

6

7

8

8

10

11*

12*

MSI-D

.

1

D

1

S

.

0

5

0

0

.

T

.

D60

.

С

1

0

1

1

1

1

Series:

MSI-D - Sensor rod with detached electronics

2

Flange Type:

1 - Threaded flange Ø 34,5 mm

2 - Threaded flange M18 × 1.5, rod Ø10 mm (standart)

3 - Threaded flange Ø 26,92 mm

3

Connection type:

D1S - Side connection. Polyurethane cable, 250 mm long

D2S - Side connection. Polyurethane cable, 400 mm long

D3S - Side connection. Polyurethane cable, 600 mm long

R4B - Bottom connection. Single wires with a flat connector, length 170 mm

R5B - Bottom connection. Single wires with a flat connector, length 230 mm

R6B - Bottom connection. Single wires with a flat connector, length 350 mm

4

Measuring Range:

0025...3800 mm, 1 mm step

Other lengths available on request

5

Zero Point:

T - 50 mm

B - 30 mm

6

Connection:

D54 – 5-pin M12 male / 5-pin M12 female / 4-pin M8 male

D60 – 6-pin M16 male (sensor equipped with integrated bus terminator)

D61 – 6-pin M16 male

D62 – 2 × 6-pin M16 male

S92 – 5-pin M12 male

S94 – 5-pin M12 male / 5-pin M12 female

7

Output Signal:

С - CAN

8

Data protocol:

101 - CANbasic (CAN 2.0A)

207 - CANbasic, multi-position

304 - CANopen, single position (standard)

9

Baud Rate:

1 - 1000 Kbit/s

2 - 500 Kbit/s

3 - 250 Kbit/s

4 - 125 Kbit/s

10

Resolution:

1 - 5 µm

2 - 2 µm

11*

Node Address:

12*

Number of Magnets:

Z02 – 2 positions

Z03 – 3 positions


*Only for C207

Default node address: 125.

It can be changed using the USB-CANbasic programmer MSI-252-382-D62

Technical data

OUTPUT PARAMETERS

Measured quantity

Position

Operating range, L

25 — 3800  mm, 1 mm step

Movement speed

Any

Cycle time

0.5 ms up to 1200 mm; 1.0 ms up to 2400 mm;

2.0 ms up to 3800 mm;

Status diagnostics

LEDs next to the connector

INTERFACE

Digital interface

CAN

Data protocols:

CANopen: Standart CIA DS 301 V3.0

CANbasic: CAN 2.0 A

Number of magnet

1-3

Max cable length:

Сable length, m: 

Transmission Speed, Kbit/s

25

<1000


100

<500


250

<250


Recommended cable length: ≤ 20 m

POSITION MEASUREMENT ACCURACY

Linearity deviation

< ± 0.01 % F.S. (minimum ± 40 µm)

Repeatability

< ± 0.001 % F.S. (minimum ± 2.5 µm)

OPERATING CONDITIONS

Operating temperature

-40 °C…+85 °C

Rated pressure

350 bar, 600 bar peak (optional 800 bar)

Humidity

90 % rel. humidity, no condensation

Ingress protection 

IP65, IP67 at cable outletat cable outlet

MATERIALS

Sensor electronics housing

Anodized aluminum, plastic

Sensor rod

Stainless steel ASTM A269-13 / TP304l (10x1.5)

Flange

Stainless steel 08Х18Н10 / AISI 304

MOUNTING

Mounting position

Any orientation. For horizontal installation of sensors with an operating range exceeding 1000 mm, the rod must be supported or fixed at the end

Flange parameters

Flange thread: M18х1.5 or 3/4" - 16 UNF

Position magnet attachment

Mounting hardware and screws made of non-magnetic material

ELECTRICAL CONNECTION

Operating voltage

+24 VDC (−15/+20 %)

Polarity protection

Up to −30 VDC

Overvoltage protection

Up to 36 VDC

Current consumption

50…140 mA (depending on stroke length)

Dielectric strength

500 VDC (DC ground to machine ground)

STANDARDS, EMC TESTS

Shock test

100 g, single shock according to IEC 60068-2-7

Vibration test

15 g / 10–2000 Hz according to IEC 60068-2-6

EMC Tests

GOST R IEC 61326-1-2014

Connector wiring: D54

PIN CONFIGURATION

PIN

OUTPUT

M12-A male connector  PORT №1

(View on sensor)

1

CAN_GND

2

-

3

-

4

CAN_HIGH

5

CAN_LOW

M12-A 

female PORT №2

(View on sensor)

1

CAN_GND

2

-

3

-

4

CAN_HIGH

5

CAN_LOW

M12-A male

(View on sensor)

1

+24 VDC (−15/+20 %)

2

-

3

DC Ground (0 V)

4

-

Connector wiring: D60

PIN CONFIGURATION

PIN

OUTPUT

M16 male

(View on sensor)

1

CAN_LOW

2

CAN_HIGH

3

-

4

-

5

+24 VDC (−15/+20 %)

6

DC Ground (0 V)

Connector wiring: D61

PIN CONFIGURATION

PIN

OUTPUT

M16 male

(View on sensor)


1

CAN_LOW

2

CAN_HIGH

3

-

4

-

5

+24 VDC (−15/+20 %)

6

DC Ground (0 V)

Connector wiring: D62

PIN CONFIGURATION

PIN

OUTPUT

M16 male PORT №1

(View on sensor)

1

CAN_LOW

2

CAN_HIGH

3

-

4

-

5

+24 VDC (−15/+20 %)

6

DC Ground (0 V)

M16 male PORT №2

(View on sensor)

1

CAN_LOW

2

CAN_HIGH

3

-

4

-

5

+24 VDC (−15/+20 %)

6

DC Ground (0 V)

Connector wiring: S92

PIN CONFIGURATION

PIN

OUTPUT

M12-A male

(View on sensor)

1

CAN_GND

2

+24 VDC (−15/+20 %)

3

DC Ground (0 V)

4

CAN_HIGH

5

CAN_LOW

Connector wiring: S94

PIN CONFIGURATION

PIN

OUTPUT

M12-A male

(View on sensor)

1

CAN_GND

2

+24 VDC (−15/+20 %)

3

DC Ground (0 V)

4

CAN_HIGH

5

CAN_LOW

Installation recommendations

РАЗНОВИДНОСТЬ ПОДКЛЮЧЕНИЯ ЭЛЕКТРОНИКИ

С нижним подключением электроники

С боковым подключением электроники

РАЗНОВИДНОСТЬ ПРИСОЕДИНЕНИЯ №1

Встраиваемый фланец Ø34,5 для нижнего подключения электроники:

Встраиваемый фланец Ø34,5 для бокового подключения электроники:

Рекомендации по монтажу

РАЗНОВИДНОСТЬ ПРИСОЕДИНЕНИЯ №2

Фланец M18x1.5 (стандарт) для нижнего подключения электроники

Фланец M18x1.5 (стандарт) для бокового подключения электроники

Рекомендации по монтажу

РАЗНОВИДНОСТЬ ПРИСОЕДИНЕНИЯ №3

Встраиваемый фланец Ø26,92 для нижнего подключения электроники

Встраиваемый фланец Ø26,92 для бокового подключения электроники

Рекомендации по монтажу

ПРИМЕР УСТАНОВКИ ДАТЧИКА В ГИДРОЦИЛИНДР

Встраиваемый датчик Ø29,92мм с нижним подключением электроники

Фланец M18x1,5 (стандарт) с боковым подключением электроники

* Нулевая точка указывается при заказе датчика и может быть установлена на расстоянии 30 или 50 мм

* Немагнитная распорка №1 устанавливается, только в том случае, если нулевая точка находится на расстоянии 30 мм
от фланца датчика линейного положения и гильза датчика выполнена из магнитного материала.

Interface

CAN Bus Interface

The position sensors operate as slave devices and fully comply with the CAN-Bus standard (ISO 11898).

The maximum data transmission rate is up to 1 Mbit/s.

Protocol Versions

1. CANopen
Complies with the encoder profile DS-406 V3.1 and standard CiA DS-301 V4.02.
CANopen functionality is based on configurable communication objects, which are set via the configuration tool.
Service Data Object (SDO)
Used for sensor parameterization. Parameters include resolution for position and velocity, installation type, operating distance and start position for up to three magnets.
Process Data Object (PDO)
Used for real-time data transmission in 8-byte frames. PDOs transmit position, velocity, limit values, slider control and operating distance for up to three magnets.
Data formats: position = 32 bit, velocity = 16 bit. Limit value = 8 bit.
•PDO Transmission Type: Asynchronous (cycle time 1 to 65535 ms) or synchronous
•SYNC Object – synchronization object
•Emergency Object – error message handling
•Node Guarding Object – network supervision
•Heartbeat Function – node monitoring
•Electronics temperature can be monitored via CAN bus

2. CANbasic
Provides simple and fast integration into control systems via direct bus access. No additional configuration tools are required, as parameters are factory-preset. The CANbasic protocol complies with CAN 2.0A and always includes the following application data for single-magnet operation:
position, velocity, sensor status, five set points.

3. CANbasic Multi-Position Measurement
Enables position measurement using up to three magnets on one sensor.
Configuration and operation are performed via the local control system according to the operating instructions.
The data protocols for all CAN versions are factory-implemented in the sensor processor, allowing all variants to be connected directly to industrial CAN networks.
CANopen sensors are certified under compliance test number: CiA199902-301V30/I-004, issued by the CAN in Automation (CiA) organization.

Multi-position measurement

MULTI-POSITION MEASUREMEN

Connection example

ELECTRONICS CONNECTION OPTIONS

BOTTOM CONNECTION

SIDE CONNECTION

CONNECTION TYPE No. 1

Threaded flange Ø 34,5 mm, side connection:

Threaded flange Ø 34,5 mm, bottom connection:

Installation recommendations:

CONNECTION TYPE No. 2

Фланец M18x1.5 (стандарт) для нижнего подключения электроники

Фланец M18x1.5 (стандарт) для бокового подключения электроники

Installation recommendations:

CONNECTION TYPE No.3

Встраиваемый фланец Ø26,92 для нижнего подключения электроники

Встраиваемый фланец Ø26,92 для бокового подключения электроники

Installation recommendations:

EXAMPLE OF SENSOR INSTALLATION IN A HYDRAULIC CYLINDER

Встраиваемый датчик Ø29,92мм с нижним подключением электроники

Фланец M18x1,5 (стандарт) с боковым подключением электроники

* The zero position is specified when ordering the sensor and can be set at a distance of 30 mm or 50 mm

* Non-magnetic spacer No. 1 is required only when the zero position is set at 30 mm from the linear position sensor flange and the sensor sleeve is made of magnetic material.

Status diagnostics


LED DIAGNOSTICS


GREEN

RED

STATUS

Off

Off

No power supply or sensor fault

On

Off

Normal operation

On

On

No position magnet or incorrect number of magnets

Flashing

Off

Programming mode ( analog output only)

Interchangeability

MSIBalluffTemposonics
MSI-H EtherCATBTL7 -Y/Z- Series – EtherCATR-Series V RH5 EtherCAT
MSI-H ProfinetBTL7 -Y/Z- Series - ProfinetR-Series V RH5 Profinet
MSI-H AnalogBTL7 -Y/Z- Series - Analog voltageR-Series V RH5 Analog
MSI-H SSIBTL7 -Y/Z- Series – SSIR-Series V RH5 SSI
MSI-H AnalogBTL7 -Y/Z- Series - Analog currentR-Series V RH5 Analog
MSI-H SSIBTL7 -A/B- Series – SSIR-Series V RH5 SSI
MSI-H EtherCATBTL7 -A/B- Series – EtherCATR-Series V RH5 EtherCAT
MSI-H ProfinetBTL7 -A/B- Series – ProfinetR-Series V RH5 Profinet
MSI-H AnalogBTL7 -A/B- Series - Analog voltageR-Series V RH5 Analog
MSI-H AnalogBTL7 -A/B- Series - Analog currentR-Series V RH5 Analog
MSI-H CANopenBTL5 -Y/Z- Series – CANopenR-Series RH CANopen
MSI-H ProfinetBTL5 -Y/Z- Series – ProfibusR-Series V RH5 Profinet
MSI-H CANopenBTL5 -A/B- Series - CANopenR-Series RH CANopen
MSI-H ProfibusBTL5 -A/B- Series - ProfibusR-Series RH Profibus
MSI-P analog или MSI-PB analogBTL B1 - Profile PA – AnalogR-Series V RP5 analog
MSI-PB analogBTL C1 - Profile PF – AnalogR-Series V RP5 analog
MSI-P analog или MSI-PB analogBTL C1 - Profile PA – AnalogR-Series V RP5 analog
MSI-P analog или MSI-PB analogBTL B1 - Profile PA – AnalogR-Series V RP5 analog
MSI-P SSIBTL7 -P- Series – DigitalR-Series V RP5 SSI
MSI-PB analogBTL7 -P- Series - Analog voltageR-Series V RP5 analog
MSI-P SSIBTL7 -P- Series – SSIR-Series V RP5 SSI
MSI-PB analogBTL7 -P- Series - Analog currentR-Series V RP5 analog
MSI-P EtherCATBTL7 -P- Series – EtherCATR-Series V RP5 EtherCAT
MSI-P ProfinetBTL7 -P- Series – ProfinetR-Series V RP5 Profinet
MSI-P analog или MSI-PB analogBTL6 -PF- Series - Analog voltageR-Series V RP5 analog
MSI-P analog или MSI-PB analogBTL6 -PF- Series - Analog currentR-Series V RP5 analog
MSI-P или MSI-PB Start/StopBTL6 -A1- Series – DigitalE-Series EP2 Start/Stop
MSI-P EtherCATBTL6 -A1- Series – EtherCATR-Series V RP5 EtherCAT
MSI-P analog или MSI-PB analogBTL6 -A1- Series - Analog voltageR-Series V RP5 analog
MSI-P CANopenBTL5 -P- Series – CANopenE-Series RP CANopen
MSI-P ProfibusBTL5 -P- Series – ProfibusE-Series RP Profibus
MSI-P или MSI-PB Start/StopBTL7 -BE/BF- Serie - DigitalE-Series EP2 Start/Stop
MSI-P SSIBTL7 -BE/BF- Serie – SSIR-Series V RP5 SSI
MSI-P или MSI-PB Start/StopBTL7 -ZE/ZF- Serie – DigitalE-Series EP2 Start/Stop
MSI-P ProfibusBTL5 -P- Series – ProfibusE-Series RP Profibus
MSI-H Start/StopBTL7 -BE/BF- Serie - DigitalE-Series EH Start/Stop
MSI-H SSIBTL7 -BE/BF- Serie – SSIR-Series V RH5 SSI
MSI-H Start/StopBTL7 -ZE/ZF- Serie – DigitalE-Series EH Start/Stop
MSI-H SSIBTL7 -ZE/ZF- Serie – SSIR-Series V RH5 SSI
MSI-H Start/StopBTL7 -CE- Serie – DigitalE-Series EH Start/Stop
MSI-H SSIBTL7 -CE- Serie – SSIR-Series V RH5 SSI
MSI-H Start/StopBTL7 -CD- Series – DigitalE-Series EH Start/Stop
MSI-H AnalogBTL7 -CD- Series - Analog voltageR-Series V RH5 Analog
MSI-H SSIBTL7 -CD- Series – SSIR-Series V RH5 SSI
MSI-H AnalogBTL7 -CD- Series - Analog currentR-Series V RH5 Analog
MSI-B AnalogBTL7 -K- Series - Analog voltage
MSI-B AnalogBTL7 -K- Series - Analog current
MSI-H CANopenBTL5 -W- Series – CANopenR-Series RH CANopen
MSI-H CANopenBTL5 -WB- Series - CANopenR-Series RH CANopen
MSI-H Start/StopBTL5 -WB- Series – DigitalE-Series EH Start/Stop
MSI-H Start/StopBTL5 -W- Series – DigitalE-Series EH Start/Stop
MSI-H CANopenBTL5 -HB- Series – CANopenR-Series RH CANopen
MSI-H Start/StopBTL5 -HB- Series – DigitalE-Series EH Start/Stop
MSI-H CANopenBTL5 -K- Series – CANopenR-Series RH CANopen
MSI-H Start/StopBTL5 -K- Series – DigitalE-Series EH Start/Stop
MSI-B SSIBTL5 -K- Series – SSI
MSI-FR-Series V RF5 R-Series V RFV
MSI-DR-Series V RDV
MSI-H DeviceNetR-Series RH DeviceNet
MSI-H DeviceNetR-Series RP DeviceNet
MSI-P DeviceNetE-Series RP DeviceNet

Downloads

Technical drawing

v.2.2 от 20.11.25

PDF

22 МБ

22 МБ

CAN Protocol Settings

от 01.10.25

PDF

5 МБ

5 МБ

Technical drawing

01.04.2025

PDF

11 МБ

11 МБ

Certificates

Contact us

    © MSISU 2026. All rights reserved