MSI-D Series Magnetostrictive Linear Position Sensor with Analog Output

Rod-style, high-precision, absolute, non-contact magnetostrictive position sensor with remote electronics, featuring a measuring range from 25 to 3800 mm.
Position measurement is performed using ring-type position magnets that move along the waveguide without physical contact.
The sensor flange is made of high-quality stainless steel and is designed for long-term industrial operation.

Price on request

CONFIGURATOR
CONTACT US

Design Features

  • Adjustable node address and zero position
  • Modular design allows fast replacement without depressurizing the hydraulic circuit
  • Compatible with all Temposonics position magnets and selected BALLUFF magnets
  • Zero position offset of 50 mm, 30 mm, or customer-specific value
  • Measurement start point from the sensor housing by default
  • Absolute linear measurement (output signals proportional to magnet displacement)
  • LED status indicator for diagnostics
  • High accuracy: resolution up to 5 µm
  • Measuring length from 25 to 3800 mm (1 mm increments)
  • Linearity < 0.01 % F.S.
  • Repeatability < 0.001 % F.S.
  • Operating temperature up to +85 °C
  • Optional operating pressure up to 800 bar
  • Protection class IP67

Configurator

MSI-D

.

_

_

.

_

.

_

.

_

_

.

_

MSI-D Series Magnetostrictive Linear Position Sensor with Analog Output, order code:

Scope of delivery

THE SCOPE OF SUPPLY INCLUDES:

Linear position sensor

Certificate of Conformity

Manual

Warranty card

Mating connectors and magnets for the sensor must be ordered separately!

Product ordering code

TECHNICAL REQUIREMENTS FOR ORDER PLACEMENT

1

2

3

4

5

6

7

MSI-D

.

S

.

D1S

.

0025

.

T

.

D60

.

A

0

1

X

X

X

X

1

Series:

MSI-D - Rod-Type

2

Flange Type:

1 – Embeddable flange Ø 34.5 mm

2 – M18x1.5 flange (standard)

3 – Embeddable flange Ø 26.92 mm

3

Connection type:

D1S – Side connection. PUR cable, length 250 mm

D2S – Side connection. PUR cable, length 400 mm

D3S – Side connection. PUR cable, length 600 mm

R4B – Bottom connection. Single wires with flat connector, length 170 mm

R5B – Bottom connection. Single wires with flat connector, length 230 mm

R6B – Bottom connection. Single wires with flat connector, length 350 mm

4

Measuring Range:

0025...3800 mm, 1 mm step

Other lengths available on request

5

Zero Point:

T - 50 mm

B - 30 mm

6

Connection:

D34 – M12 (5-pin) male connector

D60 – M16 (6-pin) male connector

S32 – M16 (8-pin) male connector

S115 – M12 (8-pin) male connector

R02 – PVC cable without connector, 2 m; option: R01...R20 (1...20 m)

H02 – PUR cable without connector, 2 m; option: H01...H20 (1...20 m)

T02 – PTFE cable without connector, 2 m; option: T01...T20 (1...20 m)

S02 – Silicone cable without connector, 2 m; option: S01...S20 (1...20 m)

W02 – Moisture-resistant cable without connector, 2 m; option: W01...W20 (1...20 m)

7

Output Signal:

1 output with 1 position magnet

V01 – Output 1: 0…10 V

V11 – Output 1: 10…0 V

V21 – Output 1: -10…10 V

V31 – Output 1: 10…-10 V

V41 – Output 1: 0…5 V

V51 – Output 1: 5…0 V

V61 – Output 1: -5…5 V

A01 – Output 1: 4…20 mA

A11 – Output 1: 20…4 mA

A21 – Output 1: 10…20 mA

A31 – Output 1: 20…0 mA

A41 – Output 1: 0…24 mA

A51 – Output 1: 24…0 mA

2 outputs with 2 position magnets

V02 – Output 1: 0…10 V; Output 2: 0…10 V

V12 – Output 1: 10…0 V; Output 2: 10…0 V

V22 – Output 1: -10…10 V; Output 2: -10…10 V

V32 – Output 1: 10…-10 V; Output 2: 10…-10 V

V42 – Output 1: 0…5 V; Output 2: 0…5 V

V52 – Output 1: 5…0 V; Output 2: 5…0 V

V62 – Output 1: -5…5 V; Output 2: -5…5 V

A02 – Output 1: 4…20 mA; Output 2: 4…20 mA

A12 – Output 1: 20…4 mA; Output 2: 20…4 mA

A22 – Output 1: 0…20 mA; Output 2: 0…20 mA

A32 – Output 1: 20…0 mA; Output 2: 20…0 mA

A42 – Output 1: 0…24 mA; Output 2: 0…24 mA

A52 – Output 1: 24…0 mA; Output 2: 24…0 mA

2 outputs with 1 position magnet

V03 – Output 1: 0…10 V; Output 2: 10…0 V

V04 – Output 1: 10…-10 V; Output 2: -10…10 V

A03 – Output 1: 4…20 mA; Output 2: 20…4 mA

A04 – Output 1: 4…20 mA; Output 2: 0…10 V

A24 – Output 1: 4…20 mA; Output 2: 10…0 V

2 outputs with 1 position magnet (position + velocity*)

V01 xxxx – Output 1: 0…10 V; Output 2 (velocity): 0…10 V

V11 xxxx – Output 1: 10…0 V; Output 2 (velocity): 10…0 V

A01 xxxx – Output 1: 4…20 mA; Output 2 (velocity): 4…20 mA

A11 xxxx – Output 1: 20…4 mA; Output 2 (velocity): 20…4 mA

Velocity range 1: 0.1…10 m/s (0001…0100)

Example 1: (-5.5…0…5.5 m/s = 10…0…10 V) = V01 0055

Velocity range 2: 25…90 mm/s (1025…1090)

Example 2: (-50…0…50 mm/s = 4…12…20 mA) = A41 1050

Technical data

OUTPUT PARAMETERS

Measured quantity

Position

Operating range, L

25 — 3800 mm, 1 mm step

Velocity

0.025 - 10 m/s

Movement speed

Any

Cycle time

0.5 ms up to 1200 mm; 1.0 ms up to 2400 mm;

2.0 ms up to 3800 mm;

Status diagnostics

LEDs next to the connector

INTERFACE

Analog interface

For voltage (control input impedance: > 5 kΩ)

For current (min./max. load resistance: 0/500 Ω)

Number of magnet

1-2

Max cable length

For stable operation, it is recommended to use a cable no longer than 35 meters

POSITION MEASUREMENT ACCURACY

Linearity deviation

< ± 0.01 % ( ± 40 µm)

Repeatability

< ± 0.001 % F.S. (minimum ± 2.5 µm)

VELOCITY MEASUREMENT ACCURACY

Velocity resolution

0.1 mm/s

Linearity error

< 0.5 %

OPERATING CONDITIONS

Operating temperature

-40 °C…+85 °C

Rated pressure

350 bar, 600 bar peak (optional 800 bar)

Humidity

90 % rel. humidity, no condensation

Ingress protection 

IP65, IP67 at cable outletat cable outlet

MATERIALS

Sensor electronics housing

Anodized aluminum

Sensor rod

Stainless steel ASTM A269-13 / TP304l (10x1.5)

Flange

Stainless steel 08Х18Н10 / AISI 304

MOUNTING

Mounting position

Any orientation. For horizontal installation of sensors with an operating range exceeding 1000 mm, the rod must be supported or fixed at the end

Flange parameters

Flange thread M18х1.5, M22 x 1.5 or 3/4" - 16 UNF

Position magnet attachment

Mounting hardware and screws made of non-magnetic material

ELECTRICAL CONNECTION

Operating voltage

For L < 2500: +12/24 VDC (-10% / +20%)

For L > 2500: +24 VDC (-15% / +20%)

Reverse polarity protection

up to –30 V DC

Overvoltage protection

up to 36 V DC

Current consumption

50…140 mA (depending on sensor length)

Insulation resistance

500 V DC (between sensor housing and 0 V DC)

STANDARDS, EMC TESTS

Shock test

100 g, single shock according to IEC 60068-2-7

Vibration test

15 g / 10–2000 Hz according to IEC 60068-2-6

EMC Tests

GOST R IEC 61326-1-2014

Connector wiring: cable

CABLE

PIN


FUNCTION

D34

D60

S115

S32

Black

2

1

5

1

Output 1: position

White

5

2

2

2

0 VDC Output 1

Yellow

4

3

3

3

Output 2: position or velocity

Green

5

4

2

-

0 VDC Output 2

-

-

-

5

Output 3: position

Red

1

5

7

7

+24 VDC (-15% / +20%)

Blue

3

6

6

6

0 VDC (power supply)

Connector wiring: D60

PIN CONFIGURATION D60

PIN

OUTPUT

M16 male connector

(view from sensor side)

1

Output 1: position

2

0 VDC output №1

3

Output 2: position or velocity

4

0 VDC output №2

5

+24 VDC (-15% / +20%)

6

0 VDC (power supply)

AVAILABLE OUTPUT SIGNAL COMBINATIONS FOR D60 CONNECTION CONFIGURATION WITH CABLE OUTLET

Description

Interface order code

Output 1

Output 2

1 output with 1 position magnet

V01

0…10 V

Not applicable 

V11

10…0 V

V21

-10…10 V

V31

10…-10 V

V41

0…5 V

V51

5…0 V

V61

-5…5 V

A01

4…20 mA

A11

20…4 mA

A21

0…20 mA

A31

20…0 mA

A41

0…24 mA

A51

24…0 mA

2 outputs with 2 position magnets

V02

0…10 V

0…10 V

V12

10…0 V

10…0 V

V22

-10…10 V

-10…10 V

V32

10…-10 V

10…-10 V

V42

0…5 V

0…5 V

V52

5…0 V

5…0 V

V62

-5…5 V

-5…5 V

A02

4…20 mA

4…20 mA

A12

20…4 mA

20…4 mA

A22

0…20 mA

0…20 mA

A32

20…0 mA

20…0 mA

A42

0…24 mA

0…24 mA

A52

24…0 mA

24…0 mA

2 outputs with 1 position magnet

V03

0…10 V

10…0 V

V04

10…-10 V

-10…10 V

A03

4…20 mA

20…4 mA

A04

4…20 mA

0…10 V

2 outputs with 1 position magnet (position + velocity)

V01 xxxx

0…10 V

0…10 V

V11 xxxx

10…0 V

10…0 V

A01 xxxx

4…20 mA

4…20 mA

A11 xxxx

20…4 mA

20…4 mA

Connector wiring: S32

PIN CONFIGURATION S32

PIN

OUTPUT

M16 male connector (view from sensor side)

1

Output 1: position

2

0 VDC output №1, №2, №3

3

Output 2: position

4

Not applicable 

5

Output 3: position

6

0 VDC (power supply)

7

+24 VDC (-15% / +20%)

8

Not applicable 

AVAILABLE OUTPUT SIGNAL COMBINATIONS FOR THE CONNECTION CONFIGURATION

Description

Interface order code

Output 1

Output 2

Output 3

1 output with 1 position magnet

A01

4…20 mA

Not applicable 

Not applicable 

A21

0…20 mA

A11

20…4 mA

A31

20…0 mA

2 outputs with 1 position magnet

V03

Not applicable 

0…10 V

10…0 V

Installation recommendations

ELECTRONICS CONNECTION OPTIONS

BOTTOM CONNECTION

SIDE CONNECTION

CONNECTION TYPE No. 1

Threaded flange Ø 34,5 mm, side connection:

Threaded flange Ø 34,5 mm, bottom connection:

Installation recommendations:

CONNECTION TYPE No. 2

M18x1.5 flange (standard) for bottom electronics connection

M18x1.5 flange (standard) for side electronics connection

Installation recommendations:

CONNECTION TYPE No.3

Threaded flange Ø26.92 mm for bottom electronics connection

Threaded flange Ø26.92 mm for side electronics connection

Installation recommendations:

EXAMPLE OF SENSOR INSTALLATION IN A HYDRAULIC CYLINDER

Threaded Ø29,92 mm with bottom connection

M18x1.5 flange (standard) for bottom electronics connection

* The zero position is specified when ordering the sensor and can be set at a distance of 30 mm or 50 mm

* Non-magnetic spacer No. 1 is required only when the zero position is set at 30 mm from the linear position sensor flange and the sensor sleeve is made of magnetic material.

Interface

Analog output
The analog sensor connects directly to the control system or indicator. The integrated microelectronics provide normalized output signals proportional to the position.

VOLTAGE OUTPUT:

CURRENT OUTPUT:

Multi-position measurement

A sensor with an analog interface can process signals from two position magnets located on the same waveguide. To obtain position information for each magnet, two conditions must be met:

  • Measurements must be taken with a spacing of at least 75 mm.

  • The sensor configuration (specified at the time of order) must support multi-position measurement.

OPERATING MODES

Application options

• Single-position sensor (standard) for position or velocity measurement.

• Dual-position sensor for simultaneous measurement of two positions.

Connection example

CONNECTION DIAGRAM FOR DEVICE WITH ACTIVE SENSING CHANNEL

CONNECTION DIAGRAM FOR DEVICE WITH PASSIVE SENSING CHANNEL

Setting

The main difference between an analog signal and a digital signal is that the analog signal has a reference point. When replacing a failed sensor, equipment recalibration is required in most cases. This can be performed in two ways:

  • If the customer’s machine includes a calibration function, new end positions are assigned in the control system after sensor replacement by moving the mechanism manually.

  • Alternatively, using the MSI-253 124 handheld programmer, new end position values can be programmed directly into the sensor. The procedure is similar to the first method; however, in this case the values are stored in the sensor rather than in the customer’s control system.

MSI-253 124 HANDHELD PROGRAMMER

Description:

Handheld programmer for analog sensors of the following series:

MSI-H,

MSI-P,

MSI-D,

MSI-F.

Functions:

Programming of the measuring range, output signal inversion.

Scope of delivery:

Handheld programmer art. no.: MSI-253 124 (1 pc.),

Power supply 220 VAC → 24 VDC (1 pc.),

Connection cable for sensor interface (1 pc.),

User manual.

Status diagnostics


LED DIAGNOSTICS


GREEN

RED

STATUS

Off

Off

No power supply or sensor fault

On

Off

Normal operation

On

On

No position magnet or incorrect number of magnets

Flashing

Off

Programming mode ( analog output only)

Interchangeability

MSIBalluffTemposonics
MSI-H EtherCATBTL7 -Y/Z- Series – EtherCATR-Series V RH5 EtherCAT
MSI-H ProfinetBTL7 -Y/Z- Series - ProfinetR-Series V RH5 Profinet
MSI-H AnalogBTL7 -Y/Z- Series - Analog voltageR-Series V RH5 Analog
MSI-H SSIBTL7 -Y/Z- Series – SSIR-Series V RH5 SSI
MSI-H AnalogBTL7 -Y/Z- Series - Analog currentR-Series V RH5 Analog
MSI-H SSIBTL7 -A/B- Series – SSIR-Series V RH5 SSI
MSI-H EtherCATBTL7 -A/B- Series – EtherCATR-Series V RH5 EtherCAT
MSI-H ProfinetBTL7 -A/B- Series – ProfinetR-Series V RH5 Profinet
MSI-H AnalogBTL7 -A/B- Series - Analog voltageR-Series V RH5 Analog
MSI-H AnalogBTL7 -A/B- Series - Analog currentR-Series V RH5 Analog
MSI-H CANopenBTL5 -Y/Z- Series – CANopenR-Series RH CANopen
MSI-H ProfinetBTL5 -Y/Z- Series – ProfibusR-Series V RH5 Profinet
MSI-H CANopenBTL5 -A/B- Series - CANopenR-Series RH CANopen
MSI-H ProfibusBTL5 -A/B- Series - ProfibusR-Series RH Profibus
MSI-P analog или MSI-PB analogBTL B1 - Profile PA – AnalogR-Series V RP5 analog
MSI-PB analogBTL C1 - Profile PF – AnalogR-Series V RP5 analog
MSI-P analog или MSI-PB analogBTL C1 - Profile PA – AnalogR-Series V RP5 analog
MSI-P analog или MSI-PB analogBTL B1 - Profile PA – AnalogR-Series V RP5 analog
MSI-P SSIBTL7 -P- Series – DigitalR-Series V RP5 SSI
MSI-PB analogBTL7 -P- Series - Analog voltageR-Series V RP5 analog
MSI-P SSIBTL7 -P- Series – SSIR-Series V RP5 SSI
MSI-PB analogBTL7 -P- Series - Analog currentR-Series V RP5 analog
MSI-P EtherCATBTL7 -P- Series – EtherCATR-Series V RP5 EtherCAT
MSI-P ProfinetBTL7 -P- Series – ProfinetR-Series V RP5 Profinet
MSI-P analog или MSI-PB analogBTL6 -PF- Series - Analog voltageR-Series V RP5 analog
MSI-P analog или MSI-PB analogBTL6 -PF- Series - Analog currentR-Series V RP5 analog
MSI-P или MSI-PB Start/StopBTL6 -A1- Series – DigitalE-Series EP2 Start/Stop
MSI-P EtherCATBTL6 -A1- Series – EtherCATR-Series V RP5 EtherCAT
MSI-P analog или MSI-PB analogBTL6 -A1- Series - Analog voltageR-Series V RP5 analog
MSI-P CANopenBTL5 -P- Series – CANopenE-Series RP CANopen
MSI-P ProfibusBTL5 -P- Series – ProfibusE-Series RP Profibus
MSI-P или MSI-PB Start/StopBTL7 -BE/BF- Serie - DigitalE-Series EP2 Start/Stop
MSI-P SSIBTL7 -BE/BF- Serie – SSIR-Series V RP5 SSI
MSI-P или MSI-PB Start/StopBTL7 -ZE/ZF- Serie – DigitalE-Series EP2 Start/Stop
MSI-P ProfibusBTL5 -P- Series – ProfibusE-Series RP Profibus
MSI-H Start/StopBTL7 -BE/BF- Serie - DigitalE-Series EH Start/Stop
MSI-H SSIBTL7 -BE/BF- Serie – SSIR-Series V RH5 SSI
MSI-H Start/StopBTL7 -ZE/ZF- Serie – DigitalE-Series EH Start/Stop
MSI-H SSIBTL7 -ZE/ZF- Serie – SSIR-Series V RH5 SSI
MSI-H Start/StopBTL7 -CE- Serie – DigitalE-Series EH Start/Stop
MSI-H SSIBTL7 -CE- Serie – SSIR-Series V RH5 SSI
MSI-H Start/StopBTL7 -CD- Series – DigitalE-Series EH Start/Stop
MSI-H AnalogBTL7 -CD- Series - Analog voltageR-Series V RH5 Analog
MSI-H SSIBTL7 -CD- Series – SSIR-Series V RH5 SSI
MSI-H AnalogBTL7 -CD- Series - Analog currentR-Series V RH5 Analog
MSI-B AnalogBTL7 -K- Series - Analog voltage
MSI-B AnalogBTL7 -K- Series - Analog current
MSI-H CANopenBTL5 -W- Series – CANopenR-Series RH CANopen
MSI-H CANopenBTL5 -WB- Series - CANopenR-Series RH CANopen
MSI-H Start/StopBTL5 -WB- Series – DigitalE-Series EH Start/Stop
MSI-H Start/StopBTL5 -W- Series – DigitalE-Series EH Start/Stop
MSI-H CANopenBTL5 -HB- Series – CANopenR-Series RH CANopen
MSI-H Start/StopBTL5 -HB- Series – DigitalE-Series EH Start/Stop
MSI-H CANopenBTL5 -K- Series – CANopenR-Series RH CANopen
MSI-H Start/StopBTL5 -K- Series – DigitalE-Series EH Start/Stop
MSI-B SSIBTL5 -K- Series – SSI
MSI-FR-Series V RF5 R-Series V RFV
MSI-DR-Series V RDV
MSI-H DeviceNetR-Series RH DeviceNet
MSI-H DeviceNetR-Series RP DeviceNet
MSI-P DeviceNetE-Series RP DeviceNet

Downloads

Technical Documentation

v.2.2 – 20.11.25

PDF

22 МБ

22 МБ

Technical drawing

01.04.2025

PDF

11 МБ

11 МБ

Certificates
Metrological verification

24.06.2024

PDF

618 КБ

618 КБ

24.06.2024

PDF

5 МБ

5 МБ

Contact us

    © MSISU 2026. All rights reserved