MSI-P Series Linear Position Sensors with DeviceNet Output

Profile-style, high-precision, absolute, non-contact magnetostrictive position sensor with a measuring range of 25 to 4000 mm.
Position is measured by position magnets that travel along the waveguide with a maximum air gap of up to 10 mm.

Price on request

CONFIGURATOR
CONTACT US

Design features

    

  • The modular design allows fast servicing and repair without releasing pressure from the hydraulic circuit.
  • The sensor is compatible with all BALLUFF position magnets and with selected magnets from Temposonics.
  • The sensor provides absolute linear measurement, with output signals proportional to the displacement of the position magnet.
  • An LED indicator is provided for sensor diagnostics.
  • The sensor delivers high accuracy with resolution up to 1 μm.
  • Measuring length is available from 25 to 4000 mm with 1 mm increments.
  • Linearity: < 0.01 %
  • Repeatability: < 0.001 %
  • Operating temperature: up to 85 °C
  • Protection class: IP67
  • The sensor supports the use of water-resistant and Teflon cables.

 

Configurator

MSI-P

.

_

.

_

.

T

.

_

.

C202

_

_

1

_

MSI-P Series Linear Position Sensors with DeviceNet Output, order code:

Scope of delivery

THE SCOPE OF SUPPLY INCLUDES:

Linear position sensor

Certificate of Conformity

Manual

Warranty card

Mounting brackets

For L < 500: 2 clamping brackets

Fot L > 500: 2 clamping brackets + 1 additional clamping bracket every 500 mm

Mating connectors and magnets for the sensor must be ordered separately!

Product ordering code

TECHNICAL REQUIREMENTS FOR ORDER PLACEMENT

1

2

3

4

5

6

7

8

9

10*

MSI-P

.

S

.

0

5

0

0

.

T

.

D60

.

С

1

0

1

1

1

1

Series:

MSI-P - Profile housing

2

Magnet type:

Without magnet

S Magnetic slider “S”, mechanically coupled, free travel

SP – Magnetic slider “SP”, mechanically coupled, close-fit design

L – Position magnet “L”, air gap up to 10 mm

K – Position magnet “K”, air gap up to 4 mm

3

Measuring range:

0025...4000 mm, 1 mm step

Other lengths available on request

4

Zero point:

T - 13 mm

5

Connection:

D60 – 6-pin male connector, M16 (sensor with integrated bus terminator)

D61 – 6-pin male connector, M16

6

Output signal:

C202 - DeviceNet

7

Data rate:

1 – 500 kbit/s

2 – 250 kbit/s

– 125 kbit/s

8

Resolution:

1 – 5 μm

2 – 2 μm

9

Type:

1 – Standard

10*

Option 1:

Not applicable / None

ER1: Extending rod with stabilizer for standard sensor mounting.

Technical specifications

OUTPUT PARAMETERS

Measured value

Position

Operating range, L

25 — 4000 mm, 1 mm step

Displacement speed

Any

Update rate

0.5 ms up to 1200 mm; 1.0 ms up to 2400 mm;

2.0 ms up to 4000 mm;

Status diagnostics

LEDs next to the connector

INTERFACE

Digital interface

CAN FieldBus System ISO 11898

Data protocol

DeviceNet v. 2.0

Number of magnets

1

Max cable length

For stable operation, it is recommended to use a cable no longer than 50 meters.

POSITION MEASUREMENT ACCURACY

Linearity

< ± 0.01 % F.S. (minimum ± 40 µm)

Repeatability

< ± 0.001 % F.S. (minimum ± 2.5 µm)

OPERATING CONDITIONS

Operating temperature

-40 °C…+85 °C

Rated pressure

350 bar, 600 bar peak (optional 800 bar)

Humidity

90 % rel. humidity, no condensation

Ingress protection 

IP65, IP67 at cable outlet

MATERIALS

Sensor electronics housing

Anodized aluminum, plastic

Sensor rod

Stainless steel ASTM A269-13 / TP304l (10x1.5)

Flange

Stainless steel 08Х18Н10 / AISI 304

MOUNTING

Mounting position

Any

For L < 500: Use 2 clamping brackets

For L > 500: Add 1 clamping bracket every 500 mm

Profile

Movable mounting brackets

Position magnet mounting

Mounting hardware and screws made of non-magnetic material

ELECTRICAL CONNECTION

Operating voltage

For L < 2500: +12/24 VDC (-10% / +20%)

For L > 2500: +24 VDC (-15% / +20%)

Reverse polarity protection

up to −30 VDC

Overvoltage protection

up to 36 VDC

Current consumption

50…140 mA (depending on stroke length)

Insulation resistance

500 VDC (DC ground to machine ground)

STANDARDS, EMC TESTS

Shock test

100 g, single shock according to IEC 60068-2-7

Vibration test

15 g / 10–2000 Hz according to IEC 60068-2-6

EMC tests

GOST R IEC 61326-1-2014

Connection: cable outlet

Connection: D60 connector

PIN ASSIGNMENT

PIN

FUNCTION

M16 male

(View on sensor)

1

CAN_LOW

2

CAN_HIGH

3

-

4

-

5

+24 VDC (−15/+20 %)

6

DC Ground (0 V)

Connection: D61 connector

PIN ASSIGNMENT

PIN

FUNCTION

M16 male

(View on sensor)

1

CAN_LOW

2

CAN_HIGH

3

-

4

-

5

+24 VDC (−15/+20 %)

6

DC Ground (0 V)

Interface

DeviceNet – a protocol based on the CAN (Controller Area Network) standard.
DeviceNet supports a maximum data transmission rate of 500 kbit/s. Positioning resolution can reach up to 2 μm.

Network topology – bus. Nodes can be easily removed and added, reducing production downtime, increasing network flexibility, and shortening troubleshooting time. Up to 64 devices can be connected to the network.

Installation of a sensor with a DeviceNet interface is quick and simple. Sensor parameters are written to the PLC using an Electronic Data Sheet (EDS).

Default node settings:
Address – 63
Data transmission rate – 500 kbit/s

DeviceNet protocol data frame

Setting

Status diagnostics


LED DIAGNOSTICS


GREEN

RED

STATUS

Off

Off

No power supply or sensor fault

On

Off

Normal operation

On

On

No position magnet or incorrect number of magnets

Flashing

Off

Programming mode ( analog output only)

Interchangeability

Downloads

Technical documentation

v.2.2 – 20.11.25

PDF

9 МБ

9 МБ

01.04.2025

PDF

8 МБ

8 МБ

Certificates

Contact a specialist

    © MSISU 2026. All rights reserved