MSI-P Series Magnetostrictive Linear Position Sensors In Profile Housing With SSI Output
Profile-style, high-precision, absolute, non-contact magnetostrictive position sensor with a measuring range of 25 to 4000 mm.
Position is measured by position magnets that travel along the waveguide with a maximum air gap of up to 10 mm.
Price on request
Design Features
- The modular design allows fast servicing and repair without releasing pressure from the hydraulic circuit.
- The sensor is compatible with all BALLUFF position magnets and with selected magnets from Temposonics.
- The sensor provides absolute linear measurement, with output signals proportional to the displacement of the position magnet.
- An LED indicator is provided for sensor diagnostics.
- The sensor delivers high accuracy with resolution up to 1 μm.
- Measuring length is available from 25 to 4000 mm with 1 mm increments.
- Linearity: < 0.01 %
- Repeatability: < 0.001 %
- Operating temperature: up to 85 °C
- Protection class: IP67
- The sensor supports the use of moisture-resistant and Teflon cables.
Configurator
MSI-P
.
_
.
_
.
T
.
_
_
.
S
_
_
_
1
_
_
MSI-P Series Magnetostrictive Linear Position Sensors In Profile Housing With SSI Output, order code:
Scope of delivery
THE SCOPE OF SUPPLY INCLUDES: | |
Linear position sensor | |
Certificate of Conformity | |
Manual | |
Warranty card | |
Mating connectors and magnets for the sensor must be ordered separately! | |
Product ordering code
TECHNICAL REQUIREMENTS FOR ORDER PLACEMENT | |||||||||||||||||||||
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12* | ||||||||||
MSI-P | . | L | . | 0 | 5 | 0 | 0 | . | T | . | D70 | . | S | 1 | B | 2 | 1 | 0 | 0 | . | ER1 |
1 | Series: MSI-P - Profile Housing | ||||||||||||||||||||
2 | Magnet type: - Without magnet S – "S" magnetic carrier, mechanical coupling, free movement SP – "SP" magnetic carrier, mechanical coupling, tight fit L – "L" position magnet, air gap up to 10 mm K – "K" position magnet, air gap up to 4 mm R - M18 x 1.5, резьба M4 в конце, шток Ø 10 мм | ||||||||||||||||||||
3 | Measuring Range: 0025...4000 mm, 1 mm step Other lengths available on request | ||||||||||||||||||||
4 | Zero Point: T - 13 mm | ||||||||||||||||||||
5 | Connection: D70 – M16 (7-pin) male connector S32 – M16 (8-pin) male connector D84 – M12 (8-pin) male connector R02 – PVC cable without connector, 2 m; option: R01...R20 (1...20 m) H02 – PUR cable without connector, 2 m; option: H01...H20 (1...20 m) T02 – PTFE cable without connector, 2 m; option: T01...T20 (1...20 m) S02 – Silicone cable without connector, 2 m; option: S01...S20 (1...20 m) W02 – Moisture-resistant cable without connector, 2 m; option: W01...W20 (1...20 m) | ||||||||||||||||||||
6 | Output Signal: S - SSI | ||||||||||||||||||||
7 | Parallel code length: 1 – 25 bits 2 – 24 bits 3 – 26 bits | ||||||||||||||||||||
8 | Coding: B – Binary G – Gray code | ||||||||||||||||||||
9 | Resolution: | ||||||||||||||||||||
mm | μ | ||||||||||||||||||||
1 - 0,005 2 - 0,01 3 - 0,05 4 - 0,1 5 - 0,02 6 - 0,002 7 - 0,04 8 - 0,001 | 5 10 50 100 20 2 40 1 | ||||||||||||||||||||
10 | Version: 1 – Standard | ||||||||||||||||||||
11 | Options: 00 – Forward measuring direction, asynchronous mode 01 – Reverse measuring direction, asynchronous mode 02 – Forward measuring direction, synchronous mode 05 – Forward measuring direction, with 26-bit parallel code length: 25 bits = alarm; 26 bits = parity check 16 – Forward measuring direction, synchronous mode, internal linearization | ||||||||||||||||||||
12* | Option 2: – None ER1 – Extending rod with stabilizer for standard sensor mounting | ||||||||||||||||||||
Technical data
OUTPUT PARAMETERS | ||||
Measured quantity | Position | |||
Operating range, L | 25 — 4000 mm, 1 mm step | |||
Movement speed | Any | |||
Update rate | 0.5 ms up to 1200 mm; 1.0 ms up to 2400 mm; 2.0 ms up to 4000 mm; | |||
Status diagnostics | LEDs next to the connector | |||
INTERFACE | ||||
Digital Interface | RS 422 | |||
Data Transfer Protocol | SSI – Synchronous Serial Interface Data format: Binary coding or Gray code (24...26 bits) | |||
Number of magnet | 1 | |||
Max cable length | Cable length, m: Baud rate, Mbit/s: | <3 1000 | <50 <400 | <100 <300 |
For stable operation, it is recommended to use a cable no longer than 20 meters with a data transmission rate not exceeding 500 kBaud. | ||||
POSITION MEASUREMENT ACCURACY | ||||
Linearity deviation | < ± 0.01 % F.S. (minimum ± 40 µm) | |||
Repeatability | < ± 0.001 % F.S. (minimum ± 2.5 µm) | |||
OPERATING CONDITIONS | ||||
Рабочая температура | -40 °C…+85 °C | |||
Номинальное давление | 350 bar, 600 bar peak (optional 800 bar) | |||
Точка росы, влажность | 90 % rel. humidity, no condensation | |||
Класс защиты | IP65, IP67 at cable outletat cable outlet | |||
MATERIALS | ||||
Sensor electronics housing | Anodized aluminum | |||
Profile | Aluminum | |||
Flange | Stainless steel 08Х18Н10 / AISI 304 | |||
MOUNTING | ||||
Mounting position | Any For L < 500: Use 2 clamping brackets For L > 500: Add 1 clamping bracket every 500 mm | |||
Profile | Movable mounting brackets | |||
Position magnet mounting | Brackets and screws made of non-magnetic material | |||
ELECTRICAL CONNECTION | ||||
Operating voltage | For L < 2500: +12/24 VDC (-10% / +20%) For L > 2500: +24 VDC (-15% / +20%) | |||
Reverse polarity protection | up to –30 V DC | |||
Overvoltage protection | up to 36 V DC | |||
Current consumption | 50…140 mA (depending on sensor length) | |||
Insulation resistance | 500 V DC (between sensor housing and 0 V DC) | |||
STANDARDS, EMC TESTS | ||||
Shock test | 100 g, single shock according to IEC 60068-2-7 | |||
Vibration test | 15 g / 10–2000 Hz according to IEC 60068-2-6 | |||
EMC Tests | GOST R IEC 61326-1-2014 | |||
Connector wiring: cable
WIRE | PIN | FUNCTION | ||
D70 | S32 | |||
Black | 1 | 5 | Data (-) | |
White | 2 | 2 | Data (+) | |
Yellow | 3 | 1 | Clock (+) | |
Green | 4 | 3 | Clock (-) | |
Red | 5 | 7 | +24 VDC (-15 / +20 %) | |
Blue | 6 | 6 | 0 VDC (Power supply) | |
Connector wiring: D70
D70 CONNECTOR PIN ASSIGNMENT | PIN | FUNCTION |
![]() M16 male (view from sensor side) | 1 | Data (-) |
2 | Data (+) | |
3 | Clock (+) | |
4 | Clock (-) | |
5 | +24 VDC (-15 / +20 %) | |
6 | 0 VDC (Power supply) | |
7 | Not connected |
Connector wiring: S32
S32 CONNECTOR PIN ASSIGNMENT | PIN | FUNCTION |
![]() M16 male (view from sensor side) | 1 | Clock (+) |
2 | Data (+) | |
3 | Clock (-) | |
4 | Not connected | |
5 | Data (-) | |
6 | 0 VDC (Power supply) | |
7 | +24 VDC (-15 / +20 %) | |
8 | Not connected |
Connector wiring: D84
PIN CONFIGURATION D84 | PIN | OUTPUT |
M12 male connector (view from cable entry side) | 1 | Clock (+) |
2 | Clock (-) | |
3 | Data (+) | |
4 | Data (-) | |
5 | Not connected | |
6 | Not connected | |
7 | +24 VDC (-15 / +20 %) | |
8 | 0 VDC (Power supply) |
Installation recommendations

Interface
SSI PROTOCOL TIMING DIAGRAM |
![]() This oscillogram shows a standard SSI transmission. Channel 1 reads the clock signal "Clock (+)" Channel 2 reads the binary code "Data (+)" The interval between two transmissions (Monoflop time) is 16 microseconds. This performance corresponds to Temposonics V series sensors. As a result, our sensors are compatible with all controllers currently available on the market.** |
Более подробно про синхронно-последовательный интерфейс (SSI) можно почитать в данной статье.
Connection example
DEVICE CONNECTION DIAGRAM |
![]() |
Setting
When replacing a failed sensor, recalibration of the equipment is required in most cases. This can be done in two ways:
- If the customer’s machine has a calibration function, after replacing the sensor, the operator assigns the new end positions to the machine’s control system by moving the mechanism in manual mode.
- Using the MSI-253 135 programmer, the new zero point value can be programmed directly into the sensor. The procedure is similar to the first method, but in this case, the value is assigned to the sensor rather than to the customer’s machine.
MSI-253 135 PROGRAMMER | |
![]() | Description: USB-SSI programmer for digital sensors of the following series: MSI-H, MSI-P, MSI-D, MSI-F, MSI-B. Functions: Zero point programming; Ability to modify all SSI parameters; Sensor functionality diagnostics. |
Scope of delivery: Programmer art. no. MSI-253 135 for SSI linear position sensors (1 pc.); Power supply 220 VAC → 24 VDC (1 pc.); USB cable (1 pc.); Ring-shaped position magnet art. no. MSI-201 542-2 (1 pc.); Connection cable for sensor with D70 connector (1 pc.); Connection cable for sensor with S32 connector (1 pc.); User manual (1 pc.). | |
Status diagnostics
LED DIAGNOSTICS | GREEN | RED | STATUS |
![]() | Off | Off | No power supply or sensor fault |
On | Off | Normal operation | |
On | On | No position magnet or incorrect number of magnets | |
Depends on status | Off | Programming mode, accessible via USB-SSI programmer art. no. MSI-253 135 |
Interchangeability
КОД ЗАКАЗА | АНАЛОГИ от Balluff |
_ _ _ _ измеряемая длина (в мм) ** длина кабеля (в метрах) | |
Frequently Ordered Accessories
Downloads
Technical documentation
Certificates
Inquiry Form
Contact us