MSI-F Series Magnetostrictive Linear Position Sensor with Profibus Output
Flexible, high-accuracy absolute non-contact magnetostrictive position sensor for stroke lengths from 900 up to 20,000 mm.
Position measurement is performed using ring-type position magnets moving along the waveguide without mechanical contact, ensuring wear-free operation and long service life.
The sensor flange is made of high-grade stainless steel, providing excellent durability and suitability for harsh industrial environments.
The MSI-F supports sensor lengths of up to 20 meters. Thanks to the flexible waveguide design, the sensor can be supplied in compact packaging (900 × 900 × 100 mm), allowing safe transportation regardless of the measuring length.
Price on request
Design Features
- Flexible waveguide design
- Absolute linear measurement (output signals proportional to magnet displacement)
- LED status indicator for sensor diagnostics
- Durable non-contact sensing technology
- High accuracy: resolution up to 1 µm
- Measuring length from 900 to 20 000 mm in 1 mm increments
- Linearity < 0.01%
- Repeatability < 0.001%
- PTFE-coated waveguide
Configurator
MSI-F
.
_
.
_
.
_
.
_
.
P
_
_
_
MSI-F Series Magnetostrictive Linear Position Sensor with Profibus Output, order code:
Scope of delivery
THE SCOPE OF SUPPLY INCLUDES: | |
Linear position sensor | |
Certificate of Conformity | |
Manual | |
Warranty card | |
Mating connectors and magnets for the sensor must be ordered separately! | |
Product ordering code
TECHNICAL REQUIREMENTS FOR ORDER PLACEMENT | ||||||||||||||||||||||
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8* | 8* | ||||||||||||||
MSI-F | . | M | . | 0 | 0 | 9 | 0 | 0 | . | T | . | D53 | . | P | . | 1 | 0 | 1 | ||||
1 | Series: MSI-F - Flexible | |||||||||||||||||||||
2 | Flange Type: M – M18 x 1.5, rod Ø 10 mm S – 3/4″ – 16 UNF, rod Ø 10 mm | |||||||||||||||||||||
3 | Measuring Range: 00900...20000 mm, 5 mm step Other lengths available on request | |||||||||||||||||||||
4 | Zero Point: T – 50 mm (for lengths < 8000 mm) T2 – 130 mm (for lengths > 8000 mm) | |||||||||||||||||||||
5 | Connection: D53 – Interface: 5-pin male and female connector, M12-B Power supply: 4-pin male connector, M8 D63 – 6-pin male and female connector, M16 S103 – Interface: 5-pin male and female connector, M12-B Power supply: 3-pin male connector, M8 D73 – Cover with 3 cable glands | |||||||||||||||||||||
6 | Output Signal: P - Profibus-DP | |||||||||||||||||||||
7 | Position measurement mode: 101 - multi-position measurement (2–3 positions) 102 - single-position measurement (standard) | |||||||||||||||||||||
8* | Node Address | |||||||||||||||||||||
8* | Number of Magnets: Z02 - 2 positions Z03 - 3 positions *Only for P101 | |||||||||||||||||||||
Technical data
OUTPUT PARAMETERS | ||||
Measured quantity | Position | |||
Operating range, L | 900 — 20000 mm, 1 mm step | |||
Movement speed | Any | |||
Update rate | 0.5 ms up to 1200 mm; 1.0 ms up to 2400 mm; 2.0 ms up to 3800 mm 3.0 ms up to 7600 mm; 6.0 ms up to 16800 mm; 7.0 ms up to 20000 mm | |||
Status diagnostics | LEDs next to the connector | |||
INTERFACE | ||||
Digital Interface | Profibus-DP bus according to ISO 74498 | |||
Data Transfer Protocol | Profibus-DP (EN-50170) | |||
Number of magnet | 1-3 | |||
Max cable length | Cable length, m: Baud rate, Mbit/s: | <100 | <200 | <400 |
For stable operation, it is recommended to use a cable no longer than 20 meters | ||||
POSITION MEASUREMENT ACCURACY | ||||
Linearity deviation | < ± 0.01 % F.S. (minimum ± 40 µm) | |||
Repeatability | < ± 0.001 % F.S. (minimum ± 2.5 µm) | |||
OPERATING CONDITIONS | ||||
Рабочая температура | -40 °C…+85 °C | |||
Номинальное давление | 350 bar, 600 bar peak (optional 800 bar) | |||
Точка росы, влажность | 90 % rel. humidity, no condensation | |||
Класс защиты | IP65, IP67 at cable outletat cable outlet | |||
MATERIALS | ||||
Sensor electronics housing | Anodized aluminum | |||
Sensor rod | Stainless steel ASTM A269-13 / TP304l (10x1.5) | |||
Flange | Stainless steel 08Х18Н10 / AISI 304 | |||
MOUNTING | ||||
Mounting position | Any. Maximum bending radius of the flexible rod: 250 mm. | |||
Flange parameters | Flange bolt M18 x 1.5 or 3/4" -16 UNF-3A, nut M18 | |||
Position magnet attachment | Mounting hardware and screws made of non-magnetic material | |||
ELECTRICAL CONNECTION | ||||
Operating voltage | 24 (- 15 / +20 %) V DC | |||
Reverse polarity protection | up to –30 V DC | |||
Overvoltage protection | up to 36 V DC | |||
Current consumption | 50…140 mA (depending on sensor length) | |||
Insulation resistance | 500 V DC (between sensor housing and 0 V DC) | |||
STANDARDS, EMC TESTS | ||||
Shock test | 100 g, single shock according to IEC 60068-2-7 | |||
Vibration test | 15 g / 10–2000 Hz according to IEC 60068-2-6 | |||
EMC Tests | GOST R IEC 61326-1-2014 | |||
Connector wiring: D53
PIN CONFIGURATION D53 | PIN | OUTPUT |
![]() M12-B female connector (view from sensor side) | 1 | VP+5 (bus terminator) |
2 | RxD/TxD-N (bus) | |
3 | DGnd (bus terminator) | |
4 | RxD/TxD-P (bus) | |
5 | Shielded cable braid | |
![]() M12-B male connector (view from sensor side) | 1 | Не используется |
2 | RxD/TxD-N (bus) | |
3 | Не используется | |
4 | RxD/TxD-P (bus) | |
5 | Shielded cable braid | |
![]() M8 male connector (view from sensor side) | 1 | +24 VDC (-15% / +20%) |
2 | Not applicable | |
3 | 0 VDC (power supply) | |
4 | Not applicable |
Connector wiring: D63
PIN CONFIGURATION D63 | PIN | OUTPUT |
![]() M16 female connector (view from sensor side) | 1 | RxD/TxD-N (bus) |
2 | RxD/TxD-P (bus) | |
3 | DGnd (bus terminator) | |
4 | VP+5 (bus terminator) | |
5 | +24 В пост. тока (- 15 / +20 %) | |
6 | 0 В пост. тока (ист. питания) | |
![]() M16 male connector (view from sensor side) | 1 | RxD/TxD-N (bus) |
2 | RxD/TxD-P (bus) | |
3 | Не используется | |
4 | Не используется | |
5 | +24 В пост. тока (- 15 / +20 %) | |
6 | 0 В пост. тока (ист. питания) |
Connector wiring: S103
PIN CONFIGURATION S103 | PIN | OUTPUT |
![]() M12-B female connector (view from sensor side) | 1 | VP+5 (bus terminator) |
2 | RxD/TxD-N (bus) | |
3 | DGnd (bus terminator) | |
4 | RxD/TxD-P (bus) | |
5 | Shielded cable braid | |
![]() M12-B male connector (view from sensor side) | 1 | Not applicable |
2 | RxD/TxD-N (bus) | |
3 | Not applicable | |
4 | RxD/TxD-P (bus) | |
5 | Shielded cable braid | |
![]() M8 male connector (view from sensor side) | 1 | +24 VDC (-15% / +20%) |
3 | 0 VDC (power supply) | |
4 | Shielded cable braid |
Connector wiring: D73
CONNECTION DIAGRAM | PIN CONFIGURATION | PIN | OUTPUT |
Х1 | 1 | RxD/TxD-P (bus) | |
2 | RxD/TxD-N (bus) | ||
Х2 | 1 | RxD/TxD-N (bus) | |
2 | RxD/TxD-P (bus) | ||
Х3 | 1 | Preset | |
2 | - | ||
Х4 | 1 | +24 VDC (-15% / +20%) | |
2 | 0 VDC (power supply) | ||
Х5 | 1 | 0 VDC (power supply) | |
2 | +24 VDC (-15% / +20%) |
Preset Input:
• Logic level “1” > +8 V
• Logic level “0” < +2 V
• Permissible input range: up to ±35 V
• Input resistance: 5 kΩ
Using BCD address switches S1 (101) and S2 (100), the node address of the PROFIBUS sensor can be set from 3 to 99.
If the PROFIBUS sensor is the last node on the PROFIBUS line, the DIP switches T1 and T2 for the integrated PROFIBUS terminator must be switched ON.
Installation Guidelines
Flexible Waveguide
Sensors with a flexible waveguide are used in vertically mounted hydraulic cylinders and in applications requiring non-standard measuring lengths and motion profiles. The PTFE coating of the waveguide enables operation in harsh environments with high contamination levels.
Position measurement is performed using ring-type magnets moving along the sensing rod without physical contact. Installation of the flexible waveguide sensor is possible both inside hydraulic cylinders and on external equipment using special mounting clamps.
INSTALLATION WITHOUT AUXILIARY TUBE | |||
The minimum bend radius is 250 mm. Exceeding this limit may cause irreversible damage to the sensor waveguide due to stretching and deformation. ![]() | |||
INSTALLATION WITH AUXILIARY TUBE | |||
The sensor flange accommodates the installation of an auxiliary tube with the following dimensions: - Outer Ø 10 mm, inner Ø 8 mm, maximum length 8 meters ![]() - Outer Ø 12.7 mm, inner Ø 8.5 mm, maximum length 20 meters ![]() The auxiliary tube must be made of non-magnetic material. For horizontal installation, clamping brackets must be installed every 500 mm. For ordering the auxiliary tube: Ø 10 mm: order code 100HFXXXXX, where XXXXX = stroke length in mm + 150 mm Ø 12.7 mm: order code 127HFXXXXX, where XXXXX = stroke length in mm + 230 mm Example: For a sensor with a 900 mm stroke length, order code: 100HF01050 For a sensor with an 8500 mm stroke length, order code: 127HF08730 | |||
![]() |
Interface
The sensor complies with all PROFIBUS-DP requirements (EN 50170).
All measurements performed by the sensor are absolute and transmitted via RS485 at a maximum speed of 12 Mbit/s.
The PROFIBUS-DP bus allows connection of up to 32 devices on a single segment. In addition to transmitting the main measured parameter (position), PROFIBUS-DP provides advanced functions for diagnostics and configuration. These parameters are loaded onto the bus via a GSD file (device-specific technical specifications).
Key characteristics of the PROFIBUS-DP sensor:
Data transmitted by the sensor:
-
Absolute position measurement
-
Sensor status
-
Error information (magnet status)
Configurable parameters:
-
Measurement direction: forward/backward
-
Resolution: 5, 50, 100, 200, 500, 1000 µm
-
Data transmission mode: synchronous, asynchronous
-
Various data formats
Multi-position measurement
OPERATING MODES |
Data Exchange When measuring with multiple magnets, 1 byte of status data and 3 bytes of position data are transmitted per cycle. The status data byte contains: an error bit and the number of positions in the current measurement. |
![]() P102 Measurements with one magnet (standard) P101 Measurements with multiple magnets, 1–3 pcs Simultaneous measurements with up to 3 magnets, minimum distance between magnets 76 mm. |
Connection example
DIGITAL INTERFACE PROFIBUS D53 |
![]() |
DIGITAL INTERFACE PROFIBUS D53 WITH BUS CONNECTOR |
![]() |
Status diagnostics
LED DIAGNOSTICS | GREEN | RED | STATUS |
![]() | Off | Off | Sensor not connected to power supply or faulty |
On | Off | Normal operation | |
On | On | Position magnet missing or incorrect number of position magnets |
Interchangeability
| MSI | Balluff | Temposonics |
|---|---|---|
| MSI-H EtherCAT | BTL7 -Y/Z- Series – EtherCAT | R-Series V RH5 EtherCAT |
| MSI-H Profinet | BTL7 -Y/Z- Series - Profinet | R-Series V RH5 Profinet |
| MSI-H Analog | BTL7 -Y/Z- Series - Analog voltage | R-Series V RH5 Analog |
| MSI-H SSI | BTL7 -Y/Z- Series – SSI | R-Series V RH5 SSI |
| MSI-H Analog | BTL7 -Y/Z- Series - Analog current | R-Series V RH5 Analog |
| MSI-H SSI | BTL7 -A/B- Series – SSI | R-Series V RH5 SSI |
| MSI-H EtherCAT | BTL7 -A/B- Series – EtherCAT | R-Series V RH5 EtherCAT |
| MSI-H Profinet | BTL7 -A/B- Series – Profinet | R-Series V RH5 Profinet |
| MSI-H Analog | BTL7 -A/B- Series - Analog voltage | R-Series V RH5 Analog |
| MSI-H Analog | BTL7 -A/B- Series - Analog current | R-Series V RH5 Analog |
| MSI-H CANopen | BTL5 -Y/Z- Series – CANopen | R-Series RH CANopen |
| MSI-H Profinet | BTL5 -Y/Z- Series – Profibus | R-Series V RH5 Profinet |
| MSI-H CANopen | BTL5 -A/B- Series - CANopen | R-Series RH CANopen |
| MSI-H Profibus | BTL5 -A/B- Series - Profibus | R-Series RH Profibus |
| MSI-H Start/Stop | BTL7 -BE/BF- Serie - Digital | E-Series EH Start/Stop |
| MSI-H SSI | BTL7 -BE/BF- Serie – SSI | R-Series V RH5 SSI |
| MSI-H Start/Stop | BTL7 -ZE/ZF- Serie – Digital | E-Series EH Start/Stop |
| MSI-H SSI | BTL7 -ZE/ZF- Serie – SSI | R-Series V RH5 SSI |
| MSI-H Start/Stop | BTL7 -CE- Serie – Digital | E-Series EH Start/Stop |
| MSI-H SSI | BTL7 -CE- Serie – SSI | R-Series V RH5 SSI |
| MSI-H Start/Stop | BTL7 -CD- Series – Digital | E-Series EH Start/Stop |
| MSI-H Analog | BTL7 -CD- Series - Analog voltage | R-Series V RH5 Analog |
| MSI-H SSI | BTL7 -CD- Series – SSI | R-Series V RH5 SSI |
| MSI-H Analog | BTL7 -CD- Series - Analog current | R-Series V RH5 Analog |
| MSI-H CANopen | BTL5 -W- Series – CANopen | R-Series RH CANopen |
| MSI-H CANopen | BTL5 -WB- Series - CANopen | R-Series RH CANopen |
| MSI-H Start/Stop | BTL5 -WB- Series – Digital | E-Series EH Start/Stop |
| MSI-H Start/Stop | BTL5 -W- Series – Digital | E-Series EH Start/Stop |
| MSI-H CANopen | BTL5 -HB- Series – CANopen | R-Series RH CANopen |
| MSI-H Start/Stop | BTL5 -HB- Series – Digital | E-Series EH Start/Stop |
| MSI-H CANopen | BTL5 -K- Series – CANopen | R-Series RH CANopen |
| MSI-H Start/Stop | BTL5 -K- Series – Digital | E-Series EH Start/Stop |
| MSI-H DeviceNet | R-Series RH DeviceNet | |
| MSI-H DeviceNet | R-Series RP DeviceNet |
Downloads
Technical Documentation
Inquiry Form
Certificates
Contact us