Linear displacement transducer, MSI-HS series, with Start/Stop outputs

Rod-type, high-precision, absolute, contactless, magnetostrictive sensor with an operating range from 25 to 3800 mm.
Position measurements are performed using ring-shaped position magnets that move along the waveguide without physical contact.
The sensor flange is made of high-quality stainless steel and is designed for long-term operation.

Price on request

Configurator
Request a consultation

Technical Specifications

  • Compact design
  • Absolute linear measurement (output signals proportional to the displacement of the position magnet)
  • High accuracy: resolution up to 1 μm
  • Measuring range from 25 to 3800 mm, adjustable in 1 mm increments
  • Linearity < 0.01%
  • Repeatability < 0.001%
  • Operating temperature up to 75 °C
  • IP68 protection rating
  • Designed for use in harsh environments

Configurator

MSI-HS

.

_

.

_

.

T

.

_

_

.

_

Linear displacement transducer, MSI-HS series, with Start/Stop outputs, код заказа:

Scope of Supply

THE DELIVERY SET INCLUDES:

Linear position sensor

Certificate of Conformity

Documentation (datasheet / manual)

Warranty card

Mating connectors and magnets for the sensor must be ordered separately!

Sensor calibration with entry in ARSHIN is charged separately!

Order Code

TECHNICAL REQUIREMENTS FOR ORDER PLACEMENT

1

2

3

4

5

6

MSI-HS

.

M

.

0

5

0

0

.

T

.

D60

.

R

0

1

1

Series:

MSI-HS - Rod type

2

Flange type:

M - M18 × 1.5, rod Ø 10 mm

G - Insert flange 45F7, rod Ø 10 mm

3

Operating range*:

0025...3800 Step 1 mm

Other lengths available on request

4

Zero point*:

T - 50 mm

B - 27 mm

5

Connection:

D60 - 6-pin plug, M16

R02 - PVC cable without connector, 2 m; option: R01...R20 (1...20 m)

H02 - PUR cable without connector, 2 m; option: H01...H20 (1...20 m)

6

Output signal:

R01 - Start/Stop

* Range can be programmed

Technical Specifications

OUTPUT PARAMETERS

Measured quantity

Position

Operating range, L

25–3800 mm with a step of 5 mm

Movement speed

Any

Update rate

0.5 ms up to 1200 mm; 1.0 ms up to 2400 mm; 2.0 ms up to 3800 mm

INTERFACE

Digital interface

RS-485/422

Data transmission protocol

Start/Stop

Number of position magnets

1

Maximum cable length

For stable operation, it is recommended to use a cable no longer than 50 meters

POSITION MEASUREMENT ACCURACY

Linearity

< ±0.01 % FSO (minimum ±40 µm)

Repeatability

< ±0.001 % FSO (minimum ±2.5 µm)

SPEED MEASUREMENT ACCURACY

Resolution

0.1 mm/s

Deviation

< 0.5 %

OPERATING CONDITIONS

Operating temperature

-40 °C…+105 °C

Nominal pressure

350 bar, 600 bar peak (optionally 800 bar)

Dew point, humidity

Relative humidity 90% without condensation

Protection class

IP68, IP67 (with connector)

MATERIAL

Sensor head

Stainless steel 08X18H10 / AISI 304

Rod

Stainless steel ASTM A269-13 / TP304L (10×1.5)

Flange

Stainless steel 08X18H10 / AISI 304

INSTALLATION

Mounting position

Any. When the sensor is installed horizontally with an operating range exceeding 1000 mm, its rod must be supported or fixed at the end.

Flange parameters

Flange bolt M18×1.5

Position magnet mounting

Mounting and screws made of non-magnetic material

ELECTRICAL CONNECTION

Operating voltage

For L < 2500: +12/24 V DC (−10 % / +20 %)

For L > 2500: +24 V DC (−15 % / +20 %)

Reverse polarity protection

up to −30 V DC

Overvoltage protection

up to 36 V DC

Supply current

50…140 mA (depending on sensor length)

Insulation resistance

500 V DC (between sensor body and 0 V DC)

STANDARDS, EMC TESTS

Shock test

100 g — single shock according to IEC 60068-2-7

Vibration test

15 g / 10–2000 Hz according to IEC 60068-2-6

EMC tests

GOST R IEC 61326-1-2014

Connection: cable gland

Wire

D60

FUNCTION

Black

1

Stop (-)

White

2

Stop (+)

Yellow

3

Start (+)

Green

4

Start (-)

Red

5

+24 V DC (−15 % / +20 %)

Blue

6

0 V DC (power source)

For stable operation, it is recommended to use a cable no longer than 35 meters.

Connection: D60 connector

D60 CONNECTOR WIRING

CONTACT

FUNCTION

M16 plug

(view from the sensor side)

1

Stop (-)

2

Stop (+)

3

Start (+)

4

Start (-)

5

+24 V DC (−15 % / +20 %)

6

0 V DC (power supply)

Interface

DIGITAL INTERFACE START/STOP

The "Ready" signal generation indicates a new measurement cycle and occurs in the Start/Stop module simultaneously with the "Start" signal.

After the "Start" signal is generated, the Start/Stop module switches to line listening mode and waits for the "Stop" signal from the linear position sensor. The time difference (dt) between the "Start" and "Stop" signals is directly proportional to the position of the position magnet.

Connection Example

CONNECTION DIAGRAM FOR THE DEVICE (Duplex)

CONNECTION DIAGRAM FOR THE DEVICE (Half-Duplex)

Interchangeability

Files for Download

Technical Documentation

Version v.2.1 dated 24 Oct 2025

PDF

12 МБ

12 МБ

Version dated 01 Apr 2025

PDF

4 МБ

4 МБ

Certificates

Version dated 03 July 2024

PDF

503 Кб

503 Кб

Version dated 03 July 2024

PDF

2 Мб

2 Мб

Ask a Specialist

    © MSISU 2025. All rights reserved