Linear displacement transducer, MSI-HS series, with Start/Stop outputs
Rod-type, high-precision, absolute, contactless, magnetostrictive sensor with an operating range from 25 to 3800 mm.
Position measurements are performed using ring-shaped position magnets that move along the waveguide without physical contact.
The sensor flange is made of high-quality stainless steel and is designed for long-term operation.
Price on request
Technical Specifications
- Compact design
- Absolute linear measurement (output signals proportional to the displacement of the position magnet)
- High accuracy: resolution up to 1 μm
- Measuring range from 25 to 3800 mm, adjustable in 1 mm increments
- Linearity < 0.01%
- Repeatability < 0.001%
- Operating temperature up to 75 °C
- IP68 protection rating
- Designed for use in harsh environments
Configurator
MSI-HS
.
_
.
_
.
T
.
_
_
.
_
Linear displacement transducer, MSI-HS series, with Start/Stop outputs, код заказа:
Scope of Supply
THE DELIVERY SET INCLUDES: | |
Linear position sensor | |
Certificate of Conformity | |
Documentation (datasheet / manual) | |
Warranty card | |
Mating connectors and magnets for the sensor must be ordered separately! | |
Sensor calibration with entry in ARSHIN is charged separately! | |
Order Code
TECHNICAL REQUIREMENTS FOR ORDER PLACEMENT | |||||||||||||||
1 | 2 | 3 | 4 | 5 | 6 | ||||||||||
MSI-HS | . | M | . | 0 | 5 | 0 | 0 | . | T | . | D60 | . | R | 0 | 1 |
1 | Series: MSI-HS - Rod type | ||||||||||||||
2 | Flange type: M - M18 × 1.5, rod Ø 10 mm G - Insert flange 45F7, rod Ø 10 mm | ||||||||||||||
3 | Operating range*: 0025...3800 Step 1 mm Other lengths available on request | ||||||||||||||
4 | Zero point*: T - 50 mm B - 27 mm | ||||||||||||||
5 | Connection: D60 - 6-pin plug, M16 R02 - PVC cable without connector, 2 m; option: R01...R20 (1...20 m) H02 - PUR cable without connector, 2 m; option: H01...H20 (1...20 m) | ||||||||||||||
6 | Output signal: R01 - Start/Stop | ||||||||||||||
* Range can be programmed | |||||||||||||||
Technical Specifications
OUTPUT PARAMETERS | |
Measured quantity | Position |
Operating range, L | 25–3800 mm with a step of 5 mm |
Movement speed | Any |
Update rate | 0.5 ms up to 1200 mm; 1.0 ms up to 2400 mm; 2.0 ms up to 3800 mm |
INTERFACE | |
Digital interface | RS-485/422 |
Data transmission protocol | Start/Stop |
Number of position magnets | 1 |
Maximum cable length | For stable operation, it is recommended to use a cable no longer than 50 meters |
POSITION MEASUREMENT ACCURACY | |
Linearity | < ±0.01 % FSO (minimum ±40 µm) |
Repeatability | < ±0.001 % FSO (minimum ±2.5 µm) |
SPEED MEASUREMENT ACCURACY | |
Resolution | 0.1 mm/s |
Deviation | < 0.5 % |
OPERATING CONDITIONS | |
Operating temperature | -40 °C…+105 °C |
Nominal pressure | 350 bar, 600 bar peak (optionally 800 bar) |
Dew point, humidity | Relative humidity 90% without condensation |
Protection class | IP68, IP67 (with connector) |
MATERIAL | |
Sensor head | Stainless steel 08X18H10 / AISI 304 |
Rod | Stainless steel ASTM A269-13 / TP304L (10×1.5) |
Flange | Stainless steel 08X18H10 / AISI 304 |
INSTALLATION | |
Mounting position | Any. When the sensor is installed horizontally with an operating range exceeding 1000 mm, its rod must be supported or fixed at the end. |
Flange parameters | Flange bolt M18×1.5 |
Position magnet mounting | Mounting and screws made of non-magnetic material |
ELECTRICAL CONNECTION | |
Operating voltage | For L < 2500: +12/24 V DC (−10 % / +20 %) For L > 2500: +24 V DC (−15 % / +20 %) |
Reverse polarity protection | up to −30 V DC |
Overvoltage protection | up to 36 V DC |
Supply current | 50…140 mA (depending on sensor length) |
Insulation resistance | 500 V DC (between sensor body and 0 V DC) |
STANDARDS, EMC TESTS | |
Shock test | 100 g — single shock according to IEC 60068-2-7 |
Vibration test | 15 g / 10–2000 Hz according to IEC 60068-2-6 |
EMC tests | GOST R IEC 61326-1-2014 |
Connection: cable gland
Wire | D60 | FUNCTION | |
Black | 1 | Stop (-) | |
White | 2 | Stop (+) | |
Yellow | 3 | Start (+) | |
Green | 4 | Start (-) | |
Red | 5 | +24 V DC (−15 % / +20 %) | |
Blue | 6 | 0 V DC (power source) | |
For stable operation, it is recommended to use a cable no longer than 35 meters.
Connection: D60 connector
D60 CONNECTOR WIRING | CONTACT | FUNCTION |
![]() M16 plug (view from the sensor side) | 1 | Stop (-) |
2 | Stop (+) | |
3 | Start (+) | |
4 | Start (-) | |
5 | +24 V DC (−15 % / +20 %) | |
6 | 0 V DC (power supply) |
Interface
DIGITAL INTERFACE START/STOP |
![]() The "Ready" signal generation indicates a new measurement cycle and occurs in the Start/Stop module simultaneously with the "Start" signal. After the "Start" signal is generated, the Start/Stop module switches to line listening mode and waits for the "Stop" signal from the linear position sensor. The time difference (dt) between the "Start" and "Stop" signals is directly proportional to the position of the position magnet. |
Connection Example
CONNECTION DIAGRAM FOR THE DEVICE (Duplex) |
![]() |
CONNECTION DIAGRAM FOR THE DEVICE (Half-Duplex) |
Interchangeability
Files for Download
Technical Documentation
Version dated 01 Apr 2025
Certificates
Questionnaire
Ask a Specialist


